Single-molecule sensors collect statistics of single-molecule interactions, and the resulting data can be used to determine concentrations of analyte molecules. The assays are generally end-point assays and are not designed for continuous biosensing. For continuous biosensing, a single-molecule sensor needs to be reversible, and the signals should be analyzed in real time in order to continuously report output signals, with a well-controlled time delay and measurement precision. Here, we describe a signal processing architecture for real-time continuous biosensing based on high-throughput single-molecule sensors. The key aspect of the architecture is the parallel computation of multiple measurement blocks that enables continuous measurements over an endless time span. Continuous biosensing is demonstrated for a single-molecule sensor with 10,000 individual particles that are tracked as a function of time. The continuous analysis includes particle identification, particle tracking, drift correction, and detection of the discrete timepoints where individual particles switch between bound and unbound states, yielding state transition statistics that relate to the analyte concentration in solution. The continuous real-time sensing and computation were studied for a reversible cortisol competitive immunosensor, showing how the precision and time delay of cortisol monitoring are controlled by the number of analyzed particles and the size of the measurement blocks. Finally, we discuss how the presented signal processing architecture can be applied to various single-molecule measurement methods, allowing these to be developed into continuous biosensors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10294250PMC
http://dx.doi.org/10.1021/acssensors.3c00245DOI Listing

Publication Analysis

Top Keywords

continuous biosensing
16
single-molecule sensors
12
continuous
9
high-throughput single-molecule
8
signals analyzed
8
analyzed real
8
real time
8
real-time continuous
8
single-molecule sensor
8
time delay
8

Similar Publications

A Novel Approach Using LuxSit-i Enhanced Toehold Switches for the Rapid Detection of .

Biosensors (Basel)

December 2024

Military Medical Sciences Academy, Tianjin 300050, China.

() is a significant concern, as it can cause severe infections and hemolytic trauma. Given its prevalence in seawater and coastal seafood, it poses a substantial risk as a foodborne pathogen. Biosensor-based detection technology has been continuously evolving, and toehold switches have emerged as a promising area within it, especially in the detection of RNA viruses.

View Article and Find Full Text PDF

Sensing Technologies for Outdoor/Indoor Farming.

Biosensors (Basel)

December 2024

Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117576, Singapore.

To face the increasing requirement for grains as the global population continues to grow, improving both crop yield and quality has become essential. Plant health directly impacts crop quality and yield, making the development of plant health-monitoring technologies essential. Variable sensing technologies for outdoor/indoor farming based on different working principles have emerged as important tools for monitoring plants and their microclimates.

View Article and Find Full Text PDF

A Highly Stable Electrochemical Sensor Based on a Metal-Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat.

Biosensors (Basel)

December 2024

Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.

The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.

View Article and Find Full Text PDF

Plant Biosensors Analysis for Monitoring Nectarine Water Status.

Biosensors (Basel)

November 2024

Irrigation Department, Centro de Edafología y Biología Aplicada del Segura (CEBAS-CSIC), P.O. Box 164, 30100 Murcia, Spain.

The real-time monitoring of plant water status is an important issue for digital irrigation to increase water productivity. This work focused on a comparison of three biosensors that continuously evaluate plant water status: trunk microtensiometers (MTs), trunk time-domain reflectometry (TDR), and LVDT sensors. During the summer and autumn seasons (DOY 150-300), nectarine trees were subjected to four different consecutive irrigation periods based on the soil Management Allowed Deficit (MAD) concept, namely: MAD (light deficit); MAD (moderate deficit); MAD (severe deficit), and MAD (full irrigation).

View Article and Find Full Text PDF

The prevalence of foodborne diseases is continuously increasing, causing numerous hospitalizations and deaths, as well as money loss in the agri-food sector and food supply chain worldwide. The standard analyses currently used for bacteria detection have significant limitations with the most important being their long procedural time that can be crucial for foodborne outbreaks. In this study, a biosensor system able to perform robust and accurate detection of spp.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!