AI Article Synopsis

  • Duplex sequencing (DuplexSeq) is an advanced method that links DNA strands to correct sequencing errors, allowing for accurate detection of mutations in tissues.
  • A study with male rats exposed to a chemical (ENU) showed significant increases in mutation frequency within 24 hours for certain tissues and confirmed a specific mutation pattern by day 7.
  • Results from different labs showed strong agreement, marking DuplexSeq as a reliable advancement over traditional gene mutation assays for testing genetic toxicity.

Article Abstract

Unlabelled: Duplex sequencing (DuplexSeq) is an error-corrected next-generation sequencing (ecNGS) method in which molecular barcodes informatically link PCR-copies back to their source DNA strands, enabling computational removal of errors by comparing grouped strand sequencing reads. The resulting background of less than one artifactual mutation per 10 nucleotides allows for direct detection of somatic mutations. TwinStrand Biosciences, Inc. has developed a DuplexSeq-based mutagenesis assay to sample the rat genome, which can be applied to genetic toxicity testing. To evaluate this assay for early detection of mutagenesis, a time-course study was conducted using male Hsd:Sprague Dawley SD rats (3 per group) administered a single dose of 40 mg/kg N-ethyl-N-nitrosourea (ENU) via gavage, with mutation frequency (MF) and spectrum analyzed in stomach, bone marrow, blood, and liver tissues at 3 h, 24 h, 7 d, and 28 d post-exposure. Significant increases in MF were observed in ENU-exposed rats as early as 24 h for stomach (site of contact) and bone marrow (a highly proliferative tissue) and at 7 d for liver and blood. The canonical, mutational signature of ENU was established by 7 d post-exposure in all four tissues. Interlaboratory analysis of a subset of samples from different tissues and time points demonstrated remarkable reproducibility for both MF and spectrum. These results demonstrate that MF and spectrum can be evaluated successfully by directly sequencing targeted regions of DNA obtained from various tissues, a considerable advancement compared to currently used gene mutation assays.

Highlights: DuplexSeq is an ultra-accurate NGS technology that directly quantifies mutationsENU-dependent mutagenesis was detected 24 h post-exposure in proliferative tissuesMultiple tissues exhibited the canonical ENU mutation spectrum 7 d after exposureResults obtained with DuplexSeq were highly concordant between laboratoriesThe Rat-50 Mutagenesis Assay is promising for applications in genetic toxicology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197591PMC
http://dx.doi.org/10.1101/2023.05.08.539833DOI Listing

Publication Analysis

Top Keywords

genetic toxicity
8
toxicity testing
8
enu-exposed rats
8
mutagenesis assay
8
bone marrow
8
mutagenesis
5
tissues
5
adopting duplex
4
duplex sequencing™
4
sequencing™ technology
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!