Background: Patellar fractures account for 1% of all skeletal injuries. Tension band wiring using SS wire has been the most commonly practiced procedure. Although this has shown good results, many patients experience hardware related problems like pain, irritation and prominence which necessitate it's removal. Recent studies have highlighted braided sutures as a possible alternative to SS wire. The purpose of this study is to evaluate the functional and radiological outcomes and complications of TBW using SS wire versus FiberWire (a reinforced braided polyblend suture) for the treatment of displaced transverse patellar fractures.

Methods: A randomized comparative study was carried out at a tertiary care center from November 2019 to May 2021. 32 patients were randomized into two equal groups, one treated with TBW using FiberWire and the other with SS wire. Patients were followed up for a period of 20 weeks and evaluated for functional outcome using the Bostman scoring scale, radiological union, complications and hardware removal rates.

Results: The mean duration for radiological union was 12.85 weeks using FiberWire and 12.75 weeks using SS wire. The mean knee range of motion was 118.57° in the FiberWire group and 117.18° in the SS wire group. Functional scores in the FiberWire and SS wire groups were 24 (good) and 26 (good) respectively measured using the Bostman scoring scale at end of 20 weeks. Complications like hardware prominence, soft tissue irritation and hardware removal rates were significantly higher in the SS wire group with a value of 0.023.

Conclusion: SS wire is biomechanically stronger than FiberWire when used for TBW. Both implants produce comparable results with respect to union rate, ROM and functional outcome, however, FiberWire causes fewer hardware complications like prominence and pain and hence alleviates the need for a second surgical procedure for implant removal. Thus, surgical treatment of transverse and inferior pole of patella fractures with TBW using FiberWire is a better alternative to SS wire considering early rehabilitation and lesser complication rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10192484PMC
http://dx.doi.org/10.1007/s43465-022-00778-2DOI Listing

Publication Analysis

Top Keywords

wire
11
fiberwire
9
randomized comparative
8
comparative study
8
functional radiological
8
tension band
8
band wiring
8
patella fractures
8
wire versus
8
versus fiberwire
8

Similar Publications

Background: Management of the extensive soft tissue injuries remains a significant challenge in orthopedic and plastic reconstructive surgery. Since the thumb is responsible for 40% of the functions of the hand, saving and reconstructing a mangled thumb is essential for the patient's future.

Case Presentation: This case report describes the management of a severe occupational thumb injury in a 25-year-old white Persian male who sustained an occupational injury to his left thumb, resulting in extensive burn, crush injury to the distal and proximal phalanx, and severe soft tissue damage to the first metacarpal, thenar, and palmar areas.

View Article and Find Full Text PDF

Atherosclerosis and aortic aneurysms are prevalent cardiovascular diseases in the elderly, characterized by chronic inflammation and oxidative stress. This study explores the role of CircXYLT1 in regulating oxidative stress and vascular remodeling in age-related vascular diseases. RNA sequencing revealed a significant upregulation of CircXYLT1 in the vascular tissues of aged mice, highlighting its potential role in age-related vascular diseases.

View Article and Find Full Text PDF

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds resulting from incomplete burning of organic materials. This work describes the successful layer-by-layer fabrication of a novel zinc oxide nanocomposite made of zinc oxide nanoparticles, aniline, sodium dodecyl sulfate, and modified multi-walled carbon nanotubes on a stainless steel wire by electrodeposition. The coating and extraction conditions were screened, optimized, and validated using factorial design and central composite design, respectively.

View Article and Find Full Text PDF

Engineers, geomorphologists, and ecologists acknowledge the need for temporally and spatially resolved measurements of sediment clogging (also known as colmation) in permeable gravel-bed rivers due to its adverse impacts on water and habitat quality. In this paper, we present a novel method for non-destructive, real-time measurements of pore-scale sediment deposition and monitoring of clogging by using wire-mesh sensors (WMSs) embedded in spheres, forming a smart gravel bed (GravelSens). The measuring principle is based on one-by-one voltage excitation of transmitter electrodes, followed by simultaneous measurements of the resulting current by receiver electrodes at each crossing measuring pores.

View Article and Find Full Text PDF

: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!