A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

ANMCO position paper: guide to the appropriate use of the wearable cardioverter defibrillator in clinical practice for patients at high transient risk of sudden cardiac death. | LitMetric

Extended risk stratification and optimal management of patients with a permanently increased risk of sudden cardiac death (SCD) are becoming increasingly important. There are several clinical conditions where the risk of arrhythmic death is present albeit only transient. As an example, patients with depressed left ventricular function have a high risk of SCD that may be only transient if there will be a significant recovery of function. It is important to protect the patients while receiving and titrating to the optimal dose the recommended drugs that may lead to an improved left ventricular function. In several other conditions, a transient risk of SCD can be observed even if the left ventricular function is not compromised. Examples are patients with acute myocarditis, during the diagnostic work-up of some arrhythmic conditions or after extraction of infected catheters while eradicating the associated infection. In all these conditions, it is important to offer a protection to these patients. The wearable cardioverter defibrillator (WCD) is of particular importance as a temporary non-invasive technology for both arrhythmia monitoring and therapy in patients with increased risk of SCD. Previous studies have shown the WCD to be an effective and safe therapy for the prevention of SCD caused by ventricular tachycardia/fibrillation. The aim of this ANMCO position paper is to provide a recommendation for clinical utilization of the WCD in Italy, based upon current data and international guidelines. In this document, we will review the WCD functionality, indications, clinical evidence, and guideline recommendations. Finally, a recommendation for the utilization of the WCD in routine clinical practice will be presented, in order to provide physicians with a practical guidance for SCD risk stratification in patients who may benefit from this device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10194821PMC
http://dx.doi.org/10.1093/eurheartjsupp/suad101DOI Listing

Publication Analysis

Top Keywords

left ventricular
12
ventricular function
12
risk scd
12
anmco position
8
position paper
8
wearable cardioverter
8
cardioverter defibrillator
8
clinical practice
8
patients
8
risk
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!