The article from this special issue was previously published in NMR In Biomedicine , Volume 35, Issue 3, 2022. For completeness we are including the title page of the article below. The full text of the article can be read in Issue 35:3 on Wiley Online Library: https://doi.org/10.1002/nbm.4640.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.4962DOI Listing

Publication Analysis

Top Keywords

sensitivity schemes
4
schemes dynamic
4
dynamic glucose-enhanced
4
glucose-enhanced magnetic
4
magnetic resonance
4
resonance imaging
4
imaging detect
4
detect glucose
4
glucose uptake
4
uptake clearance
4

Similar Publications

Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.

Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.

View Article and Find Full Text PDF

Assessment of skeletal maturity is a common clinical practice to investigate adolescent growth and endocrine disorders. The distal radius and ulna (DRU) maturity classification is a practical and easy-to-use scheme that was designed for adolescent idiopathic scoliosis clinical management and presents high sensitivity in predicting the growth peak and cessation among adolescents. However, time-consuming and error-prone manual assessment limits DRU in clinical application.

View Article and Find Full Text PDF

PAVON has developed a malaria microscopy competency training scheme to augment competency in malaria microscopy. Here, data accrued from training activities between 2020 and 2023 in Botswana are presented. Three trainings were done for 37 central and peripheral level technicians for a two-week period.

View Article and Find Full Text PDF

Exploring Distinct Second-Order Data Approaches for Thiamine Quantification via Carbon Dot/Silver Nanoparticle FRET Reversion.

Biosensors (Basel)

December 2024

LAQV, REQUIMTE, Department of Chemical Sciences, Laboratory of Applied Chemistry, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira n° 228, 4050-313 Porto, Portugal.

Accurate and selective monitoring of thiamine levels in multivitamin supplements is essential for preventing deficiencies and ensuring product quality. To achieve this, a Förster resonance energy transfer (FRET) system using carbon dots (CDs) as energy donors and citrate-stabilized silver nanoparticles (AgNPs) as energy acceptors was developed. The aqueous synthesis of AgNPs using microwave irradiation was optimized to obtain efficient plasmonic nanoparticles for FRET applications, targeting maximal absorbance intensity, stability, and wavelength alignment.

View Article and Find Full Text PDF

A New Caffeine Detection Method Using a Highly Multiplexed Smartphone-Based Spectrometer.

Biosensors (Basel)

December 2024

Zhejiang University-University of Illinois Urbana-Champaign Institute, Zhejiang University, Haining 314400, China.

Smartphones equipped with highly integrated sensors are increasingly being recognized as powerful tools for rapid on-site testing. Here, we propose a low-cost, portable, and highly multiplexed smartphone-based spectrometer capable of collecting three types of spectra-transmission, reflection, and fluorescence-by simply replacing the optical fiber attached to the housing. Spectral analysis is performed directly on the smartphone using a custom-developed app.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!