A Randomised Trial Comparing Drug Coated Balloons and Conventional Balloons for the Treatment of Stent Graft Stenosis in Dialysis Vascular Access.

Eur J Vasc Endovasc Surg

Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan; College of Medicine, National Taiwan University, Taipei, Taiwan; Institute of Biomedical Engineering, National Tsing-Hua University, Hsinchu, Taiwan; Institute of Cellular and System Medicine, National Health Research Institutes, Zhunan, Taiwan; Centre of Quality Management, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan. Electronic address:

Published: August 2023

Objective: Previous studies on arteriovenous fistulas have demonstrated the potential benefit of drug coated balloons (DCBs) in maintaining the patency of dialysis access. However, stenoses involving stent grafts were excluded from these studies. Therefore, the aim was to evaluate the effectiveness of DCBs in treating stent graft stenosis.

Methods: This was a prospective, single blinded, randomised controlled study. From March 2017 to April 2021, 40 patients with dysfunctional vascular access owing to stent graft stenosis were randomised to treatment with a DCB or conventional balloon. Clinical follow up was scheduled at one, three, and six months, and angiographic follow up was performed six months after the intervention. The primary outcome was angiographic late luminal loss at six months, and secondary outcomes included target lesion and access circuit primary patency at six months.

Results: Thirty-six participants completed follow up angiography. The DCB group had a superior mean late luminal loss at six months compared with the control group (1.82 mm ± 1.83 mm vs. 3.63 mm ± 1.08 mm, respectively, p = .001). All 40 patients completed clinical follow up. The DCB group had a superior six month target lesion primary patency compared with the control group [hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.07 - 0.71; p = .005). Additionally, the DCB group had a numerically higher six month access circuit primary patency rate than the control group, although the difference was not statistically significant (HR 0.54, 95% CI 0.26 - 1.11, p = .095).

Conclusion: Conventional balloon angioplasty is not durable in stent graft stenosis treatment. Treatment with DCBs provides less angiographic late luminal loss and potentially superior primary patency of the target lesion than treatment with conventional balloons. [ClinicalTrials ID: NCT03360279.].

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejvs.2023.05.028DOI Listing

Publication Analysis

Top Keywords

stent graft
16
primary patency
16
graft stenosis
12
late luminal
12
luminal loss
12
target lesion
12
dcb group
12
control group
12
drug coated
8
coated balloons
8

Similar Publications

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA.

View Article and Find Full Text PDF

Ascending-to-Descending Aortic Bypass of a Thoracic Stent Graft Infection with a Rare Pathogen.

Surg Infect (Larchmt)

January 2025

Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.

Stent graft infection (SGI) caused by complex is rare. The usage of ascending-to-descending aortic bypass (ADAB) in such situations has not yet been fully discussed. Case report and literature review.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!