A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of hyperbaric exposure on mechanical and electronic parameters of implantable cardioverter-defibrillators. | LitMetric

Aims: Hyperbaric oxygen therapy (HBOT) is the standard adjuvant treatment for life-threatening or disabling pathologies. Currently, mechanical and electronic variations of implantable cardioverter-defibrillators (ICD) in hyperbaric conditions have not been evaluated. As a result, many patients eligible for HBOT but ICD recipients cannot undergo this therapy, even in emergency situations.

Methods And Results: Twenty-two explanted ICD of various brands and models were randomized in two groups: single hyperbaric exposure at an absolute pressure of 4000 hPa and 30 iterative hyperbaric exposures at an absolute pressure of 4000 hPa. Mechanical and electronic parameters of these ICD were blindly assessed before, during, and after hyperbaric exposures. Regardless of the hyperbaric exposure, we could not find any mechanical distortion, inappropriate occurrence of anti-tachycardia therapies, dysfunction of tachyarrhythmia therapeutic programming, or dysfunction of programmed pacing parameters.

Conclusion: Dry hyperbaric exposure seems harmless on ICD tested ex vivo. This result may lead to a reconsideration of the absolute contraindication of emergency HBOT to ICD recipients. A real-life study in these patients with an indication to HBOT should be performed to assess their tolerance to the treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10198771PMC
http://dx.doi.org/10.1093/europace/euad134DOI Listing

Publication Analysis

Top Keywords

hyperbaric exposure
16
mechanical electronic
12
electronic parameters
8
implantable cardioverter-defibrillators
8
hbot icd
8
icd recipients
8
absolute pressure
8
pressure 4000 hpa
8
hyperbaric exposures
8
hyperbaric
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!