We have developed a new scintillator-based optical soft x-ray (OSXR) diagnostic system for KSTAR. By utilizing fiber optic faceplates, mm-size lens arrays, and fiber bundles, we have successfully constructed a novel optical system for scintillator-based soft x-ray detection to overcome the limited vacuum-port conditions in KSTAR. P47 (Y2SiO5), which has a fast rise (∼7 ns) and decay (∼100 ns) time sufficient for detecting plasma instabilities observed in the kHz-MHz spectral range, was selected as the scintillator material for the KSTAR OSXR system. Scintillation toward each detection channel is collected by the lens arrays coupled to optical fiber cores, which are connected to the photodetector system. Initial results obtained during the 2022 KSTAR experimental campaign support the validity of the OSXR data through the consistency of OSXR measurement results with other diagnostics. We also observe that the OSXR system can capture magnetohydrodynamic activities, such as sawtooth oscillations, and provide valuable information for disruption mitigation studies using shattered pellet injection.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0146169DOI Listing

Publication Analysis

Top Keywords

soft x-ray
12
scintillator-based optical
8
optical soft
8
x-ray osxr
8
osxr diagnostic
8
diagnostic system
8
system kstar
8
lens arrays
8
osxr system
8
osxr
6

Similar Publications

-Armchair graphene nanoribbons (nAGNRs) are promising components for next-generation nanoelectronics due to their controllable band gap, which depends on their width and edge structure. Using non-metal surfaces for fabricating nAGNRs gives access to reliable information on their electronic properties. We investigated the influence of light and iron adatoms on the debromination of 4,4''-dibromo--terphenyl precursors affording poly(-phenylene) (PPP as the narrowest GNR) wires through the Ullmann coupling reaction on a rutile TiO(110) surface, which we studied by scanning tunneling microscopy and X-ray photoemission spectroscopy.

View Article and Find Full Text PDF

Convergent-beam attosecond x-ray crystallography.

Struct Dyn

January 2025

Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany.

Sub-ångström spatial resolution of electron density coupled with sub-femtosecond to few-femtosecond temporal resolution is required to directly observe the dynamics of the electronic structure of a molecule after photoinitiation or some other ultrafast perturbation, such as by soft X-rays. Meeting this challenge, pushing the field of quantum crystallography to attosecond timescales, would bring insights into how the electronic and nuclear degrees of freedom couple, enable the study of quantum coherences involved in molecular dynamics, and ultimately enable these dynamics to be controlled. Here, we propose to reach this realm by employing convergent-beam x-ray crystallography with high-power attosecond pulses from a hard-x-ray free-electron laser.

View Article and Find Full Text PDF

Sulfurized polyacrylonitrile (SPAN) exhibits a very high cycle stability by overcoming the shuttle effect of conventional Li-S batteries. However, there are still controversies in SPAN about the bonding types of sulfur with the matrix, their critical synthesis temperature regions, and their roles in the electrochemical lithium storage reaction, seriously hindering the economical synthesis of SPAN, the optimization of performances, and the exploration of other SPAN-like alternatives. The key to solving the above problems lies in accurate measurements of the thermodynamic evolution of bonding interactions in the synthesis process as well as in the electrochemical process.

View Article and Find Full Text PDF

Aim: This study aimed to evaluate the effects of chronic consumption of two sugar-sweetened carbonated soft drinks - one containing caffeine (Coca-Cola®) and one without (Sprite®) - on the progression of periapical lesions and the levels of pro-inflammatory cytokines in rats.

Methodology: Twelve Wistar rats were divided into three groups (n = 4): Control group, Coca-Cola group and Sprite group. The rats in Coca-Cola and Sprite groups were given ad libitum access to their respective soft drinks for 3 months, while the Control group received filtered water.

View Article and Find Full Text PDF

Clinical characteristics and removal of broken burs retained in the lower jaw.

BMC Oral Health

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.

Background: A broken bur retained in the lower jaw is an uncommon complication that occurs during the extraction of the impacted mandibular third molar. The purpose of this retrospective study was to investigate the clinical characteristics of the broken burs and review our experience with the removal of the broken burs in these cases.

Methods: All patients, who suffered the broken bur remained in the lower jaw due to the extraction of the impacted mandibular third molar and presented to our hospital from July 2019 to July 2024, were included in this retrospective study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!