In 2020, the global prevalence of glaucoma was estimated to be 76 million and it was projected to increase to 111.8 million by 2040. Accurate intraocular pressure (IOP) measurement is imperative in glaucoma management since it is the only modifiable risk factor. Numerous studies have compared the reliability of IOP measured using transpalpebral tonometers and Goldmann applanation tonometry (GAT). This systematic review and meta-analysis aims to update the existing literature with a reliability and agreement comparison of transpalpebral tonometers against the gold standard GAT for IOP measurement among individuals presenting for ophthalmic examinations. The data collection will be performed using a predefined search strategy through electronic databases. Prospective methods-comparison studies published between January 2000 and September 2022 will be included. Studies will be deemed eligible if they report empirical findings on the agreement between transpalpebral tonometry and Goldmann applanation tonometry. The standard deviation and limits of agreement between each study and their pooled estimate along with weights and percentage of error will be reported using a forest plot. Cochrane's Q test and the I statistic will be used to assess heterogeneity, and the publication bias will be investigated using a funnel plot, Begg's and Egger's tests. The review results will provide additional evidence on the reliability of transpalpebral tonometers that, in turn, could possibly assist practitioners to make informed decision about using it as a screening or diagnostic device for clinical practice, outreach camps, or home-based screening. Institutional Ethics Committee registration number: RET202200390. PROSPERO Registration Number: CRD42022321693.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10391437 | PMC |
http://dx.doi.org/10.4103/IJO.IJO_3321_22 | DOI Listing |
Ophthalmol Glaucoma
November 2024
Glaucoma Services, Aravind Eye Hospital, Madurai, India.
Topic: The systematic review and meta-analysis consolidates the extant body of evidence comparing reliability and agreement between Transpalpebral Tonometers (TT) and Goldmann Applanation Tonometer (GAT).
Clinical Relevance: With a global prevalence of 3.54 percent, glaucoma stands as the second leading cause of preventable blindness.
PLoS One
May 2024
Toneasy Inc., Tokyo, Japan.
Purpose: We developed a novel transpalpebral self-tonometer called the TapEye tonometer (TET) based on palpation of the upper eyelid. Our goal was to evaluate a method for improving the accuracy of measuring intraocular pressure (IOP) through the eyelid.
Methods: Participants underwent standardized training by technicians and were required to be able to use the TET for study inclusion.
Int Ophthalmol
December 2023
Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of S. Paulo - EPM/ UNIFESP, São Paulo, Brazil.
Beyoglu Eye J
September 2023
Department of Ophthalmology, Haydarpasa Numune Training and Research Hospital, Istanbul, Türkiye.
Objectives: The objective of the study is to evaluate the agreement between Goldmann applanation tonometer (GAT) and Easyton transpalpebral tonometer, Tonopen, and Icare in patients with Keratoconus.
Methods: This cross-sectional study included 46 eyes of 26 patients with keratoconus. Intraocular pressure (IOP) is measured using easyton, icare, tonopen, and GAT.
J Clin Med
July 2023
Instituto Universitario Fernández-Vega, Fundación de Investigación Oftalmológica, Universidad de Oviedo, 33012 Oviedo, Spain.
Background: The mechanism that could increase intraocular pressure (IOP) during scleral lens (SL) wear is not fully understood, although it may be related to compression of the landing zone on structures involved in aqueous humor drainage.
Methods: Thirty healthy subjects were fitted with two SLs of different sizes (L1 = 15.8 mm, L2 = 16.