AI Article Synopsis

  • A study evaluated the connection between retinal vascular fractal dimension (FD) and age in healthy eyes using advanced imaging technology.
  • It involved 222 eyes from 116 participants without any ocular or systemic diseases, employing retinal imaging techniques to analyze vascular structures.
  • Findings revealed that FD values don't significantly change with age, indicating they remain consistent across different areas of the retina, implying minimal age adjustment is needed when assessing retinal health.

Article Abstract

Purpose: This cross-sectional observational study evaluated the relationship between retinal vascular fractal dimension (FD) and age, as well as other vascular parameters in healthy eyes using swept-source optical coherence tomography angiography (SS-OCTA).

Methods: The study cohort consisted of 222 eyes of 116 healthy participants with no ocular or systemic disease. SS-OCTA images were captured and analyzed using the Plex Elite 9000 and software tools available in the advanced retinal imaging (ARI) network hub. The retinal vascular layers were defined by the instrument's automatic retinal layer segmentation. The fractal analysis was performed on the superficial capillary plexus (SCP), deep capillary plexus (DCP), and the whole retina. Grayscale OCTA images were standardized and binarized using ImageJ and fractal box-counting analyses were performed using Fractalyse software. Pearson's correlation was used to analyze the correlation between FD and retinal vascular parameters.

Results: The results showed that FD values were significantly higher in the 6 mm ring and the whole 6 × 6 scan region when compared to the 1 mm ETDRS central subfield. The correlation between age and FD was weak with a significant positive correlation between age and FD of the SCP in the 6 mm ring and between age and FD of the DCP in the 1 mm ring. Overall, differences in FD values in these healthy eyes were extremely small regardless of age or macular location.

Conclusion: FD values in normal eyes show little variation with age and are relatively stable across the macula. This suggests that FD values may not need adjustment for age or location when evaluated in the context of retinal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-023-06117-xDOI Listing

Publication Analysis

Top Keywords

healthy eyes
12
retinal vascular
12
fractal analysis
8
eyes swept-source
8
swept-source optical
8
optical coherence
8
coherence tomography
8
tomography angiography
8
capillary plexus
8
6 mm ring
8

Similar Publications

The effect of optical stimulation at a frequency of 10 Hz (OS) on temporal parameters of sensorimotor activity in healthy subjects (n=32) was studied. The expression of the activation response was determined by the ratio of spectral power values (SPα2, μV) of the high frequency (10-13 Hz) subrange of the α-rhythm of the initial EEG with closed and opened eyes and the frequency of the maximum α-peak (IAPF). A test for simple motor reaction time was performed under normal and OS conditions.

View Article and Find Full Text PDF

Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN) are severe mucocutaneous disorders characterized by extensive tissue necrosis; they are often accompanied by severe ocular complications (SOC). The regulatory role of microRNAs (miRNAs) in modulating immune responses in SJS/TEN is not fully understood, particularly in relation to chronic SOC. We explored the expression profiles of specific miRNAs and their potential impact on the regulation of key innate immune genes in patients with SJS/TEN with SOC.

View Article and Find Full Text PDF

Development and psychometric properties of a quality of life assessment tool for Chinese patients undergoing intravitreal injection (IVI-QoL-23).

Retina

January 2025

Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.

Purpose: To develop and assess the psychometric properties of a quality of life (QoL) assessment tool for Chinese patients treated with intravitreal injection (IVI) of anti-vascular endothelial growth factor (anti-VEGF).

Methods: We developed a 31-item IVI-QoL questionnaire using semi- structured patient interviews and expert panel consultation, drawing on a study of the literature. After pretesting on a subset of patients undergoing IVI, the questionnaire was pared down to 23 items.

View Article and Find Full Text PDF

Purpose: This study explores the potential interaction of brolucizumab with platelets and its effects on platelet activation and reactivity, crucial in retinal vasculitis and retinal vascular occlusion. Safety concerns remain of interest, although brolucizumab showed superior retinal efficacy and reduced injection frequency compared to other licensed anti-VEGF agents.

Methods: Resting and activated platelets of healthy volunteers were pretreated with brolucizumab at the following concentrations 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!