Background: With the constant need for technique improvement for ensuring correct diagnoses and precise treatment, imaging examinations that use contrast media have become unavoidable and indispensable. However, the long-term effects of contrast media on renal function remain unclear in populations with advanced renal failure. This study aimed to examine the relationship between contrast media exposure and long-term trends in renal function in patients with renal failure.
Methods: This retrospective cohort study included patients with a definitive diagnosis of chronic kidney disease who visited medical institutions in Japan between April 2012 and December 2020. The cohort was divided into contrast agent therapy and non-contrast agent therapy groups. The assessment indices were the number of contrast exposures and renal function decline. Renal function decline was calculated based on observed chronic kidney disease stage trends and glomerular filtration rate correspondence tables sourced from various guidelines. A stratified analysis focusing on changes in renal function while accounting for the acceleration of chronic kidney disease progression was also performed.
Results: After adjusting for patient background with propensity score matching, 333 patients each were included in both groups. The observation period was 5.3 ± 2.1 and 4.9 ± 2.2 years per case in the contrast-enhanced and non-contrast-enhanced groups, respectively. The baseline estimated glomerular filtration rate at the beginning of the observation period was 55.2 ± 17.8 mL/min/1.73 m in the contrast-enhanced groups (P = 0.65). Although only slightly different in both groups, the glomerular filtration rate change was 1.1 ± 3.3 mL/min/1.73 m/year in the contrast agent therapy group and tended to be higher with contrast media exposure. Stratified analysis showed that the annual glomerular filtration rate changes in patients with more contrast media exposures and altered renal function were 7.9 ± 7.1 mL/min/1.73 m/year and 4.7 ± 3.6 mL/min/1.73 m/year in the contrast agent therapy and non-contrast agent therapy groups, respectively (1.69 times, P < 0.05).
Conclusion: We were able to identify a clinical trend of successful measures for preventing adverse renal outcomes associated with contrast media exposure. However, increased frequency of contrast media exposure has a long-term effect on renal function in patients with altered it. Appropriate treatment choices related to contrast media may control chronic kidney disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10189938 | PMC |
http://dx.doi.org/10.1186/s12882-023-03194-2 | DOI Listing |
J Air Waste Manag Assoc
January 2025
School of Emergency Management and Safety Engineering, China University of Mining and Technology (Beijing), Beijing, China.
Dust emissions from open-pit mining pose a significant threat to environmental safety and human health. Currently, the range of dust suppressants used in coal mining is limited, often failing to account for their suitability across various stockpiles. This oversight results in poor infiltration after application, leading to insufficient crust formation and reduced durability.
View Article and Find Full Text PDFRadiology
January 2025
From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, 763G Main Bldg, Philadelphia, PA 19107 (A.L., C.K.Y.E., T.S.X., S.K.R., C.E.W., K.B., J.R.E., F.F.); Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy (F.P.); Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (F.P.); University of California San Diego, San Diego, Calif (Y.K.); University of Calgary, Calgary, Canada (A.M.K., S.R.W.); Einstein Medical Center, Philadelphia, Pa (S.K.R.); Vanderbilt University, Nashville, Tenn (V.P.); Stanford University, Stanford, Calif (A.K.); UT Southwestern Medical Center, Dallas, Tex (D.T.F.); Department of Visceral Surgery and Medicine, Bern University Hospital, University of Bern, Bern, Switzerland (A.B., I.P.R.); Department of Imaging Sciences, School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom (P.S.S.); and Department of Radiology, King's College Hospital, London, United Kingdom (P.S.S.).
Background Indeterminate focal liver observations in patients at risk for hepatocellular carcinoma (HCC) may require invasive biopsy or follow-up, which could lead to delays in definitive categorization and to postponement of treatment. Purpose To examine clinical effect of contrast-enhanced US (CEUS) in participants with high-risk indeterminate liver observations categorized as Liver Imaging Reporting and Data System (LI-RADS) category LR-4 (probably HCC) or LI-RADS category LR-M (probably or definitely malignant but not HCC specific) at CT or MRI. Materials and Methods This was a secondary analysis of a prospective international multicenter validation study for CEUS LI-RADS (January 2018 to August 2021).
View Article and Find Full Text PDFCurr Med Imaging
January 2025
Department of Radiology, Peking Union Medical College Hospital [PUMCH], Chinese Academy of Medical Sciences & Peking Union Medical College [CAMS & PUMC], China.
Aims To evaluate the utility of unenhanced spectral imaging, electron density (ED) and overlay electron density (OED) images for assessing pulmonary embolisms in patients with suspected or confirmed acute pulmonary embolism (APE). Background Multiple spectral images can be extrapolated from spectral detector CT (SDCT), ED and OED images. ED and OED images are highly sensitive to moisture-rich tissues.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of General Surgery, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
Iliac Vein Compression Syndrome (IVCS) is a common risk factor for deep vein thrombosis in the lower extremities. The objective of this study was to investigate whether employing a porous medium model to simulate the compressed region of an iliac vein could improve the reliability and accuracy of Computational Fluid Dynamics (CFD) analysis outcomes of IVCS. Pre-operative Computed Tomography (CT) scan images of patients with IVCS were utilized to reconstruct models illustrating both the compression and collateral circulation of the iliac vein.
View Article and Find Full Text PDFLuminescence
January 2025
Department of Physics, IMN, Universidad de La Laguna, San Cristobal de La Laguna, Santa Cruz de Tenerife, Spain.
Er-doped BaF single crystals were investigated with two primary aims: first, to probe the infrared emissions from the I level (around 1.0 μm) under 1500-nm excitation and, second, to use the crystal to enhance the efficiency of silicon-based solar cells through upconversion mechanism. Upon excitation at 1500 nm, the upconversion emission spectrum of the Er-doped BaF single crystals, recorded in the range of 480-1080 nm, exhibited two well-structured visible bands at 538 and 650 nm, along with a strong near infrared emission at 971 nm.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!