Purpose: To assess the safety and efficacy of a ciliary neurotrophic factor (CNTF) intraocular implant on neuroprotection and neuroenhancement in glaucoma.
Design: Open-label, prospective, phase I clinical trial.
Participants: A total of 11 participants were diagnosed with primary open-angle glaucoma (POAG). One eye of each patient was assigned as the study (implant) eye.
Methods: The study eye was implanted with a high-dose CNTF-secreting NT-501 implant, whereas the other eye served as a control. All patients were followed up for 18 months. Analysis was limited to descriptive statistics.
Main Outcome Measures: Primary outcome was safety through 18 months after implantation assessed by serial eye examinations, structural and functional testing, and adverse events (AEs) recording. Parameters measured included visual acuity (VA), Humphrey visual field (HVF), pattern electroretinogram, scanning laser polarimetry with variable corneal compensation (GDx VCC), and OCT. These parameters were also used for secondary analysis of efficacy outcome.
Results: All NT-501 implants were well tolerated with no serious AEs associated with the implant. The majority of AEs were related to the implant placement procedure and were resolved by 12 weeks after surgery. Foreign-body sensation was the most commonly reported AE and was self-limited to the postoperative period. The most common implant-related AE was pupil miosis; no patients underwent explant. Visual acuity and contrast sensitivity decreased more in fellow eyes than in study eyes (VA, -5.82 vs. -0.82 letters; and contrast sensitivity, -1.82 vs. -0.37 letters, for fellow vs. study eyes, respectively). The median HVF visual field index and mean deviation measurements worsened (decreased) in fellow eyes (-13.0%, -3.9 dB) and improved (increased) in study eyes (2.7%, 1.2 dB). Implanted eyes showed an increase in retinal nerve fiber layer thickness measured by OCT and by GDx VCC (OCT, 2.66 μm vs. 10.16 μm; and GDx VCC, 1.58 μm vs. 8.36 μm in fellow vs. study eyes, respectively).
Conclusions: The NT-501 CNTF implant was safe and well tolerated in eyes with POAG. Eyes with the implant demonstrated both structural and functional improvements suggesting biological activity, supporting the premise for a randomized phase II clinical trial of single and dual NT-501 CNTF implants in patients with POAG, which is now underway.
Financial Disclosures: Proprietary or commercial disclosure may be found after the references.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183667 | PMC |
http://dx.doi.org/10.1016/j.xops.2023.100298 | DOI Listing |
Viruses
December 2024
Department of Research, Altino Ventura Foundation (FAV), Recife 50070-040, Brazil.
Deformities, body asymmetries, and muscle contractures are common consequences of atypical postural patterns in children with c ongenital Zika syndrome (CZS). This study aimed to evaluate the posture of children with CZS, considering their neurological and visual impairments. Ophthalmological assessment included binocular best-corrected visual acuity (BCVA) using Teller Acuity Cards II (TAC II) and an ocular motility evaluation.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of General Medicine, Shizuoka Saiseikai General Hospital, Shizuoka 422-8527, Japan.
(1) Background: Delirium is a serious condition in patients undergoing treatment for somatic diseases, leading to poor prognosis. However, the pathophysiology of delirium is not fully understood and should be clarified for its adequate treatment. This study analyzed the relationship between confusion symptoms in delirium and resting-state electroencephalogram (EEG) power spectrum (PS) profiles to investigate the heterogeneity.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA.
Autonomous vehicles (AVs) offer significant potential to improve safety, reduce emissions, and increase comfort, drawing substantial attention from both research and industry. A critical challenge in achieving SAE Level 5 autonomy, full automation, is path planning. Ongoing efforts in academia and industry are focused on optimizing AV path planning, reducing computational complexity, and enhancing safety.
View Article and Find Full Text PDFSensors (Basel)
December 2024
School of Digital Media & Design Arts, Beijing University of Posts and Telecommunications, No. 10 Xitucheng Road, Beijing 100876, China.
Trust is a crucial human factor in automated supervisory control tasks. To attain appropriate reliance, the operator's trust should be calibrated to reflect the system's capabilities. This study utilized eye-tracking technology to explore novel approaches, given the intrusive, subjective, and sporadic characteristics of existing trust measurement methods.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!