The study aimed to investigate the effects of two different plasma systems, including pinhole plasma jet and gliding arc (GA) plasma, for the degradation of herbicide, diuron, in plasma activated solutions (PAS). In the GA plasma system, air was used to generate plasma, however, Ar, oxygen and nitrogen at different gas compositions were compared in the pinhole plasma jet system. The Taguchi design model was used to study the effects of gas compositions. Results revealed that the pinhole plasma jet system was able to degrade over 50% of the diuron in 60 minutes. The optimal plasma generation condition for the highest degradation of diuron used pure Ar gas. The highest degradation percentage of herbicide in PAS corresponded to the lowest hydrogen peroxide (HO) content, nitrite concentration and electrical conductivity (EC) of the PAS. The diuron degradation products were identified as 3,4-dichloro-benzenamine, 1-chloro-3-isocyanato-benzene and 1-chloro-4-isocyanato-benzene gas chromatography-mass spectrometry (GC-MS). The GA plasma system was not adequate for the degradation of herbicide in PAS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10184135PMC
http://dx.doi.org/10.1039/d3ra00459gDOI Listing

Publication Analysis

Top Keywords

pinhole plasma
12
plasma jet
12
plasma
10
degradation herbicide
8
plasma system
8
gas compositions
8
jet system
8
highest degradation
8
herbicide pas
8
degradation
6

Similar Publications

Assessing the effectiveness of advanced platelet rich fibrin in treating gingival recession: a systematic review and meta-analysis.

BMC Oral Health

November 2024

Oral Medicine, Periodontology, Diagnosis and Oral Radiology Department, Faculty of Dentistry, Mansoura University, Mansoura, 33516, Egypt.

Objectives: The literature lacks comprehensive evidence on the efficacy of advanced platelet rich fibrin(A-PRF) in treating gingival recession. Therefore, this systematic review and meta-analysis aimed to evaluate the effectiveness of A-PRF in the treatment of gingival recession.

Materials And Methods: We adhered to the guidelines of PRISMA in searching the following databases: PubMed/MEDLINE, Embase, Cochrane Library, Web of Science, and Scopus to include all the eligible studies according to the prespecified inclusion and exclusion criteria.

View Article and Find Full Text PDF

There is a strong demand for efficient second harmonic generation (SHG) in ultra-intense short-pulse lasers. This paper demonstrates the generation of an unconverted fundamental (1ω)+second harmonics (2ω) mixed laser on the LFEX laser system. The experimental setup utilizes 0.

View Article and Find Full Text PDF

Development of a bolometry diagnostic for SPARC.

Rev Sci Instrum

August 2024

Commonwealth Fusion Systems, Devens, Massachusetts 01434, USA.

To control and optimize the power of the SPARC tokamak, we require information on the total radiated power of the plasma and its 2D and 3D spatial distribution. The SPARC bolometry diagnostic is being designed and built to measure the radiated power for controlling power balance, investigating the dissipation capabilities of various divertor concepts, and measuring the efficacy of the disruption thermal load mitigation. Proven resistive bolometer sensor technology will be used, with 248 lines of sight integrated into pinhole cameras in 20 different locations.

View Article and Find Full Text PDF

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector's capability of adjusting the threshold energy at the pixel level.

View Article and Find Full Text PDF

Implementation of an impurity diagnostic suite on the Pegasus-III experiment.

Rev Sci Instrum

August 2024

Department of Nuclear Engineering and Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA.

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τshot ∼ 10 ms, ne ∼ 1 × 1019 m-3, and Te ∼ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!