Study Objectives: We aimed to evaluate the duration and frequency of communication between EMS (Emergency Medical Services) and ED (Emergency Department) staff during handoff and the subsequent time to critical cardiac care (rhythm determination, defibrillation) using CA (cardiac arrest) video review.
Methods: A single-center retrospective study of video-recorded adult CAs between August 2020 and December 2022 was performed. Two investigators assessed the communication of 17 data points, time intervals, EMS initiation of handoff, and type of EMS agency. Median times from initiation of handoff to first ED rhythm determination and defibrillation were compared between the groups above versus below the median number of data points communicated.
Results: Overall, 95 handoffs were reviewed. The handoff was initiated in a median of 2 seconds (interquartile range (IQR) 0-10) after arrival. EMS initiated handoff in 65 (69.2%) patients. The median number of data points communicated was 9 and median duration was 66 seconds (IQR 50-100). Age, location of arrest, estimated down time, and medications administered were communicated > 80% of the time, initial rhythm 79%, and bystander cardiopulmonary resuscitation and witnessed arrest < 50%. The median times from initiation of handoff to first ED rhythm determination and defibrillation were 188 (IQR 106-256) and 392 (IQR 247-725) seconds, though not statistically different between handoffs with <9 vs. ≥9 data points communicated (p > 0.40).
Conclusion: There is no standardization for handoff reports from EMS to ED staff for CA patients. Using video review, we demonstrated the variable communication during handoff. Improvements to this process could reduce the time to critical cardiac care interventions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.resuscitation.2023.109834 | DOI Listing |
J Electromyogr Kinesiol
December 2024
School of Information Science and Technology, Dalian Maritime University, Linghai Road 1, Dalian, Liaoning Province 116026, China. Electronic address:
This study proposed a U-Net based partial convolutional time-domain model for a real-time high-density surface electromyography (HD-sEMG) decomposition. The model combines U-Net and a separation block containing partial convolution, aiming to efficiently identify motor units (MUs) without preprocessing. The proposed U-Net based network was trained by the HD-sEMG signals with innervation pulse trains (IPTs) labels, and the results are compared between different step sizes, noises, and model structures under the sliding time window with 120 sampling points.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Physics, Lakehead University, Thunder Bay, Ontario, Canada.
Background: This study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer.
View Article and Find Full Text PDFPLoS One
December 2024
Group of Atmospheric Optics (GOA-UVa), Universidad de Valladolid, Valladolid, Spain.
This work introduces CAECENET, a new system capable of automatically retrieving columnar and vertically-resolved aerosol properties running the GRASP (Generalized Retrieval of Atmosphere and Surface Properties) algorithm using sun-sky photometer (aerosol optical depth, AOD; and sky radiance measurements) and ceilometer (range corrected signal; RCS) data as input. This method, so called GRASPpac, is implemented in CAECENET, which assimilates sun-sky photometers data from CÆLIS database and ceilometer data from ICENET database (Iberian Ceilometer Network). CAECENET allows for continuous and near-real-time monitoring of both vertical and columnar aerosol properties.
View Article and Find Full Text PDFPediatrics
December 2024
Department of Agricultural and Resource Economics, University of Connecticut, Storrs, Connecticut.
Objective: Breastfeeding enhances maternal and child health, yet US breastfeeding rates remain below optimal levels and substantial disparities persist. The 2022 infant formula crisis had the potential to influence infant feeding practices due to formula shortages and fears about the safety of formula feeding in the wake of recalls. This report studies the evolution of breastfeeding-initiation trends during the infant formula crisis and compares the effects across subpopulations.
View Article and Find Full Text PDFAnn Med
December 2025
Faculty of Nursing, University of Alberta, Edmonton, Alberta, Canada.
Background: Despite high COVID-19 vaccine coverage in Canada, vaccine acceptance and preferred delivery among newcomers, racialized persons, and those who primarily speak minority languages are not well understood. This national study explores COVID-19 vaccine acceptance, access to vaccines, and delivery preferences among ethnoculturally diverse population groups.
Methods: We conducted two national cross-sectional surveys during the pandemic (Dec 2020 and Oct-Nov 2021).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!