A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Au@NiFeMOFs as the signal quencher of Au@g-CNNSs composite for sensitive "on-off" electrochemiluminescence immunosensing of beta-2-microglobulin. | LitMetric

Au@NiFeMOFs as the signal quencher of Au@g-CNNSs composite for sensitive "on-off" electrochemiluminescence immunosensing of beta-2-microglobulin.

Talanta

State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, School of Chemistry and Pharmaceutical Sciences, Guangxi Normal University, Guilin 541004, China. Electronic address:

Published: August 2023

In this study, an electrochemiluminescence resonance energy transfer (ECL-RET) immunosensor was constructed to detect beta-2-microglobulin (B2M). As a donor-acceptor pair, a carbon nitride nanosheet modified with gold nanoparticles (Au@g-CNNSs) and a nickel- and iron-based organic framework modified with gold nanoparticles (Au@NiFeMOFs) were prepared. The sandwich immunosensor was successfully constructed so that ECL-RET occurred between Au@NiFeMOFs and Au@g-CNNSs. The ECL intensity of the immunosensor decreased with the increase the B2M concentration due to the low conductivity of B2M. The linear range of the ECL-RET immunosensor was from 10 fg/mL to 10 ng/mL, and the limit of detection was 2.3 fg/mL (S/N = 3). The developed immunosensor had high sensitivity, high specificity, and excellent stability. It could realize the sensitivity test of B2M and provide a novel idea for the detection of biomarkers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.124672DOI Listing

Publication Analysis

Top Keywords

ecl-ret immunosensor
8
immunosensor constructed
8
modified gold
8
gold nanoparticles
8
immunosensor
5
au@nifemofs signal
4
signal quencher
4
quencher au@g-cnnss
4
au@g-cnnss composite
4
composite sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!