The Coronavirus disease 2019 (COVID-19) pandemic presented the scientific community with an immediate need for accurate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology assays, resulting in an expansion of assay development, some without following a rigorous quality control and validation, and with a wide range of performance characteristics. Vast amounts of data have been gathered on SARS-CoV-2 antibody response; however, performance and ability to compare the results have been challenging. This study seeks to analyze the reliability, sensitivity, specificity, and reproducibility of a set of widely used commercial, in-house, and neutralization serology assays, as well as provide evidence for the feasibility of using the World Health Organization (WHO) International Standard (IS) as a harmonization tool. This study also seeks to demonstrate that binding immunoassays may serve as a practical alternative for the serological study of large sample sets in lieu of expensive, complex, and less reproducible neutralization assays. In this study, commercial assays demonstrated the highest specificity, while in-house assays excelled in antibody sensitivity. As expected, neutralization assays demonstrated high levels of variability but overall good correlations with binding immunoassays, suggesting that binding may be reasonably accurate as well as practical for the study of SARS-CoV-2 serology. All three assay types performed well after WHO IS standardization. The results of this study demonstrate there are high performing serology assays available to the scientific community to rigorously dissect antibody responses to infection and vaccination. Previous studies have shown significant variability in SARS-CoV-2 antibody serology assays, highlighting the need for evaluation and comparison of these assays using the same set of samples covering a wide range of antibody responses induced by infection or vaccination. This study demonstrated that there are high performing assays that can be used reliably to evaluate immune responses to SARS-CoV-2 in the context of infection and vaccination. This study also demonstrated the feasibility of harmonizing these assays against the International Standard and provided evidence that the binding immunoassays may have high enough correlation with the neutralization assays to serve as a practical proxy. These results represent an important step in standardizing and harmonizing the many different serological assays used to evaluate COVID-19 immune responses in the population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10269912 | PMC |
http://dx.doi.org/10.1128/spectrum.05353-22 | DOI Listing |
Background: Due to the unique geographical and climatic conditions in Nagqu (Tibet), the blood station laboratory was only fully established and accredited by 2020. This study validated the performance of the laboratory's blood screening system and analyzed recent trends in blood donation and screening effectiveness.
Methods: Various serum samples were used to assess the performance of hepatitis B, hepatitis C, HIV, and syphilis tests, both serological and nucleic acid tests.
J Clin Microbiol
January 2025
Leiden University Center for Infectious Diseases, Leiden University Medical Center, Leiden, the Netherlands.
Unlabelled: The World Health Organization (WHO) 2030 roadmap for schistosomiasis calls for development of highly sensitive and specific diagnostic tools to continue and sustain progress towards elimination. Serological assays are excellent for sensitive detection of primary schistosome infections and for schistosomiasis surveillance in near- and post-elimination settings. To develop accurate assay formats, it is necessary to identify defined antibody targets with low cross-reactivity and potential for standardized production.
View Article and Find Full Text PDFJ Helminthol
January 2025
Hacettepe University, Faculty of Medicine, Department of Radiology, Ankara, Turkiye.
Cystic Echinococcosis (CE) is a zoonotic disease caused by sensu lato. Diagnosing CE primarily relies on imaging techniques, and there is a crucial need for an objective laboratory test to enhance the diagnostic process. Today, cell-free DNAs (cfDNAs) have gained importance regarding their biomarker potential.
View Article and Find Full Text PDFTransfusion
January 2025
Cerus Corporation, Concord, California, USA.
Background: Although alloimmunization risk of pathogen-reduced (PR) platelets has been studied, the risk has not been reported with PR red blood cells (RBCs).
Study Design And Methods: In a Phase III, randomized, controlled trial (Red Cell Pathogen Inactivation), cardiac or thoracic-aorta surgery patients were randomized to transfusion with amustaline/glutathione PR versus conventional RBCs. Pre-transfusion and Day 28 samples were evaluated for Human leukocyte antigen (HLA) Class I and Class II antibodies at low, medium, and high cutoff values.
Nephrology (Carlton)
January 2025
Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, Thammasat University, Pathumthani, Thailand.
The case report presents a male patient in his mid-60s with a history of hypertension, benign prostatic hyperplasia and chronic kidney disease (CKD). He presented with gradually increasing serum creatinine levels and hyperglobulinemia, leading to suspicion of multiple myeloma. However, subsequent testing revealed features consistent with systemic lupus erythematosus (SLE) and IgG4-related kidney disease (IgG4-RKD).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!