This study proposes a deep-learning-based solution (named CapsNetCovid) for COVID-19 diagnosis using a capsule neural network (CapsNet). CapsNets are robust for image rotations and affine transformations, which is advantageous when processing medical imaging datasets. This study presents a performance analysis of CapsNets on standard images and their augmented variants for binary and multi-class classification. CapsNetCovid was trained and evaluated on two COVID-19 datasets of CT images and X-ray images. It was also evaluated on eight augmented datasets. The results show that the proposed model achieved classification accuracy, precision, sensitivity, and F1-score of 99.929%, 99.887%, 100%, and 99.319%, respectively, for the CT images. It also achieved a classification accuracy, precision, sensitivity, and F1-score of 94.721%, 93.864%, 92.947%, and 93.386%, respectively, for the X-ray images. This study presents a comparative analysis between CapsNetCovid, CNN, DenseNet121, and ResNet50 in terms of their ability to correctly identify randomly transformed and rotated CT and X-ray images without the use of data augmentation techniques. The analysis shows that CapsNetCovid outperforms CNN, DenseNet121, and ResNet50 when trained and evaluated on CT and X-ray images without data augmentation. We hope that this research will aid in improving decision making and diagnostic accuracy of medical professionals when diagnosing COVID-19.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137585 | PMC |
http://dx.doi.org/10.3390/diagnostics13081484 | DOI Listing |
Acad Radiol
January 2025
Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).
Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.
Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).
Vet Clin North Am Exot Anim Pract
January 2025
Avian and Exotic Pet Service, UQ Veterinary Medical Centre, Building 8156, Main Drive, University of Qld, Gatton, Queensland 4343, Australia. Electronic address:
Imaging of an exotic animal with gastroenteric disease is often essential to make a diagnosis. The selection of a modality and its effective use needs careful consideration in each case. Obtaining a high-quality image and its interpretation are an acquired skill.
View Article and Find Full Text PDFJ Vasc Surg Venous Lymphat Disord
January 2025
Department of Vascular Surgery, Chenzhou First People's Hospital and the First Affiliated, Hospital of Xiangnan University, Chenzhou, Hunan Province 423000, China. Electronic address:
Objective: This study sought to investigate the changes in plasma D-dimer levels during catheter-directed thrombolysis (CDT) in patients with acute lower extremity deep venous thrombosis (DVT), analyze imaging results, and assess their clinical implications.
Methods: We retrospectively analyzed 62 patients diagnosed with acute lower extremity DVT who underwent CDT between March 2019 and December 2022. Plasma D-dimer levels were measured before CDT, at regular intervals after CDT, and at the end of CDT.
Ann Endocrinol (Paris)
January 2025
Hospices Civils de Lyon, Groupement Hospitalier Est, Endocrinology Federation, Lyon, France.
At present, primary hyperparathyroidism is most often discovered in an asymptomatic patient, but can sometimes be revealed by a renal or bone complications. In all cases, a full work-up is recommended, with assessment of renal function (glomerular filtration rate), 24-hour calciuria, screening for risk factors for lithiasis, and renal and urinary tract imaging (ultrasound or CT scan) to look for stones or nephrocalcinosis. Bone densitometry, with measurements of the spine, femur and radius, is the recommended reference test for demineralization.
View Article and Find Full Text PDFNucl Med Biol
January 2025
State Research Center-Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency, 123182 Moscow, Russia. Electronic address:
Introduction: Folate receptors (FR) have been considered a convenient target for different radiopharmaceuticals in recent years. Multifarious Ga-labeled folate conjugates have been proposed as promising agents for the PET imaging of FR-overexpressing malignant neoplasms. In addition, radiolabeled folate-based conjugates can be effective for imaging non-tumor pathological foci characterized by a pronounced cluster of activated macrophages.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!