Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study.

Diagnostics (Basel)

David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

Published: April 2023

We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. In both approaches, we measured modulation transfer function (MTF) and Strehl Ratio (SR) values at 3.0 and 4.5 mm pupil sizes. We determined the through-focus (TF) MTF at 25, 50 and 100 lp/mm for the 3 mm aperture. United States Air Force (USAF) target images were recorded. MTF measurement of the trifocal lens and the combined monofocal and trifocal AddOn IOL showed good performance at the far and near focus for the 3 mm aperture. For the 4.5 mm aperture the MTF improved for the far focus but decreased for the intermediate and near focus. TF MTF showed better contrast at the far focus for the polypseudophakic setup but at the expense of the efficiency at the near focus. However, the USAF chart images revealed only minimal differences between both approaches. The optical quality of the polypseudophakic approach was not affected by the presence of two IOLs instead of one and proved to be comparable with the performance of one capsular-bag-fixated trifocal IOL. Differences between the single vs. two-lens approach seen in the TF MTF analysis could be attributed to the optical design that varied between the trifocal models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137998PMC
http://dx.doi.org/10.3390/diagnostics13081482DOI Listing

Publication Analysis

Top Keywords

intraocular lens
8
optical quality
8
trifocal
6
mtf
6
focus
5
comparison presbyopia-correcting
4
presbyopia-correcting supplementary
4
supplementary intraocular
4
lens
4
lens combination
4

Similar Publications

Objective: This study investigates the refractive accuracy of eight intraocular lens (IOL) power calculation formulas in patients with postoperative refractive surprise after phacoemulsification. It aims to determine if a different formula could result in better refractive outcomes in these eyes.

Methods And Analysis: We retrospectively reviewed consecutive patients undergoing uncomplicated phacoemulsification as a sole procedure between March 2007 and September 2020 at the University of Washington by glaucoma subspecialists as part of a study investigating cataract surgery in normal eyes.

View Article and Find Full Text PDF

Nd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery.

Turk J Ophthalmol

December 2024

University of Health Sciences Türkiye, Ulucanlar Eye Training and Research Hospital, Clinic of Ophthalmology, Ankara, Türkiye.

Cataract surgery is the most frequently performed surgery worldwide. Although it is an effective surgical treatment option for improving patients' visual acuity, various complications can occur postoperatively. One such complication is the presence of retained lens material in the anterior chamber, which can lead to intraocular inflammation, increased intraocular pressure, corneal edema, and endothelial cell loss.

View Article and Find Full Text PDF

[Cataracts extraction combined with multifocal intraocular lens optic implantation in Berger space in school-age children with cataracts].

Zhonghua Yan Ke Za Zhi

January 2025

Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, School of Ophthalmology, Shandong First Medical University, Qingdao266071, China.

To evaluate the safety and efficacy of cataract extraction combined with multifocal intraocular lens (IOL) optic implantation in Berger space in school-age children with cataracts. It was a prospective study. The clinical data of school-age children with cataract who underwent cataract extraction combined with multifocal IOL implantation at Qingdao Eye Hospital of Shandong First Medical University from January 2019 to June 2023 were collected.

View Article and Find Full Text PDF

Background: To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods: Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery.

View Article and Find Full Text PDF

Background: The new patient cataract and lens ophthalmic questionnaire (CLOQ) determines subjective patient satisfaction before and after cataract surgery according to item response theory (IRT).

Methods: A total of 317 patients with bilateral cataract surgery and implantation of different intraocular lens (IOL) types were included. The questionnaire (37 questions) is divided into questions on visual acuity-relevant quality of life (VRQoL), quality of vision (QoV), spectacle dependence, and general satisfaction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!