The present review summarizes data collected by the Swedish National Cataract Register (NCR), which by the end of 2021 contained data for more than 2.4 million cataract surgeries between 1992 and 2021. During these 30 years, the cataract surgery rate rose from 3700 to 12 800. The coverage of NCR is very high including 93% of all cataract procedures in Sweden between 2010 and 2021. Independently of demographic changes, the proportion of operations of patients age 60 to 79 has increased while the proportion of 80 to 90+ has decreased. The median visual acuity of the first eye planned for surgery was 0.1 decimal in 1992 and has increased to 0.5 decimal in 2021. Patient-reported outcome measures have been registered with the Catquest-9SF questionnaire since 2008, demonstrating intervention at an earlier stage, but consistently favorable outcomes. Surgical complications have decreased; endophthalmitis has decreased from 0.10% to below 0.02%, and posterior capsule rupture from 2.8% to 0.6%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/j.jcrs.0000000000001209 | DOI Listing |
Sci Rep
January 2025
Department of Ophthalmology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.
To describe the management and clinical course of 12 cases of pseudophakic aqueous misdirection syndrome (AMS). Twelve eyes of 12 Patients diagnosed with pseudophakic AMS between 2021 and 2022 were included. Best-corrected visual acuity, refraction, intraocular pressure (IOP), anti-glaucomatous medication, spectral domain ocular coherence tomography (SD-OCT) and postoperative complications were evaluated.
View Article and Find Full Text PDFPurpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.
Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).
Purpose: To evaluate residual refractive errors after intraocular lens (IOL) extraction and the safety and effectiveness of refractive correction procedures.
Methods: The eligibility criteria for this systematic review were patients who had undergone cataract or clear lens extraction and had experienced residual refractive error. All study designs were considered for inclusion and non-English publications, non-peer reviewed articles, books, and systematic reviews were excluded.
J Refract Surg
January 2025
Purpose: To apply a new method, the Taylor Diagram, and a new concept, the centered root mean square error (cRMSE), in evaluating the performance of IOL formulas.
Methods: The preoperative biometrics were measured with the IOLMaster 700 (Carl Zeiss Meditec) and the postoperative spherical equivalent refraction (SER) was calculated in 888 anonymous patients. The Taylor Diagram was applied to visualize the centered root mean square error (cRMSE) and the correlation coefficient between the predictions and the observations (R).
Int J Med Sci
January 2025
Department of Ophthalmology, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, China, 100044.
This research was designed to evaluate the efficacy and safety of ab-interno trabeculectomy (Trabectome and Kahook Dual Blade) combined with phacoemulsification, intraocular lens implantation, and goniosynechialysis in eyes with primary angle-closure glaucoma. A total of 47 patients were included in the study and all the patients received the combined surgery. Intraocular pressure, anti-glaucoma medications, best-corrected visual acuity, and the number of peripheral anterior synechiae quadrants were recorded at baseline and at various time points after surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!