Atrial fibrillation (AF)-induced peripheral microcirculatory alterations have poorly been investigated. The present study aims to expand current knowledge through a beat-to-beat analysis of non-invasive finger photoplethysmography (PPG) in AF patients restoring sinus rhythm by electrical cardioversion (ECV). Continuous non-invasive arterial blood pressure and left middle finger PPG pulse oximetry waveform (POW) signals were continuously recorded before and after elective ECV of consecutive AF or atrial flutter (AFL) patients. The main metrics (mean, standard deviation, coefficient of variation), as well as a beat-to-beat analysis of the pulse pressure (PP) and POW beat-averaged value (aPOW), were computed to compare pre- and post-ECV phases. 53 patients (mean age 69 ± 8 years, 79% males) were enrolled; cardioversion was successful in restoring SR in 51 (96%) and signal post-processing was feasible in 46 (87%) patients. In front of a non-significant difference in mean PP (pre-ECV: 51.96 ± 13.25, post-ECV: 49.58 ± 10.41 mmHg; p = 0.45), mean aPOW significantly increased after SR restoration (pre-ECV: 0.39 ± 0.09, post-ECV: 0.44 ± 0.06 a.u.; p < 0.001). Moreover, at beat-to-beat analysis linear regression yielded significantly different slope (m) for the PP (RR) relationship compared to aPOW(RR) [PP(RR): 0.43 ± 0.18; aPOW(RR): 1.06 ± 0.17; p < 0.001]. Long (> 95th percentile) and short (< 5th percentile) RR intervals were significantly more irregular in the pre-ECV phases for both PP and aPOW; however, aPOW signal suffered more fluctuations compared to PP (p < 0.001 in both phases). Present findings suggest that AF-related hemodynamic alterations are more manifest at the peripheral (aPOW) rather than at the upstream macrocirculatory level (PP). Restoring sinus rhythm increases mean peripheral microvascular perfusion and decreases variability of the microvascular hemodynamic signals. Future dedicated studies are required to determine if AF-induced peripheral microvascular alterations might relate to long-term prognostic effects.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10130175 | PMC |
http://dx.doi.org/10.1038/s41598-023-33952-z | DOI Listing |
J Frailty Aging
February 2025
Division of Experimental Medicine, McGill University, Montreal, QC Canada; Division of Cardiology, Jewish General Hospital, Montreal, QC Canada. Electronic address:
Background: Frailty is a syndrome associated with age-related impairments in multiple organ systems, of which the autonomic nervous system plays a fundamental role. Measurement of heart rate variability (HRV) is a non-invasive method to evaluate the autonomic activity and gain insights into cardiovascular health and potentially, frailty. A few small studies have explored the relationship between HRV and frailty, with promising but conflicting results.
View Article and Find Full Text PDFJ Appl Physiol (1985)
January 2025
School of Kinesiology and Health Studies, Queen's University, Kingston, Ontario, Canada.
Proximal limb cuff inflation to 40% arterial occlusion pressure (AOP) is assumed to reduce exercising leg perfusion, creating "blood flow restriction" (BFR). However, no study has validated this assumption. 18 healthy young participants (9F) performed two-legged knee flexion/extension exercise at 25% WRpeak with bilateral cuffs applied to the proximal thigh at 0% AOP (CTL), 20% AOP and 40% AOP.
View Article and Find Full Text PDFInt J Med Sci
January 2025
Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, Bandar Tun Razak, 56000 Cheras, Kuala Lumpur, MALAYSIA.
The finger photoplethysmography fitness index (PPGF), a marker of peripheral vascular function, has been linked to heart rate (HR) variability. However, the influence of acute HR changes on resting PPGF, a purported indicator of local blood flow, remains unclear. This study aimed to determine the influence of acute HR changes on resting PPGF.
View Article and Find Full Text PDFJ Biomed Opt
June 2024
Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States.
Significance: Pulse oximeter measurements are commonly relied upon for managing patient care and thus often require human testing before they can be legally marketed. Recent clinical studies have also identified disparities in their measurement of blood oxygen saturation by race or skin pigmentation.
Aim: The development of a reliable bench-top performance test method based on tissue-simulating phantoms has the potential to facilitate pre-market assessment and the development of more accurate and equitable devices.
Sensors (Basel)
December 2024
Internal Medicine, Kanai Hospital, 612-12, Yodokizu-cho, Fushimi-ku, Kyoto 613-0911, Japan.
Diabetes is known to reduce blood circulation in capillaries and arterioles; however, no devices can easily measure this on a daily basis. In this study, we developed a tool for measuring finger photoplethysmograms using green light and near-infrared LEDs. Thereafter, photoplethysmography was conducted on 25 inpatients/outpatients with diabetes and 21 adult males and females who had not been diagnosed with or treated for diabetes, hypertension, or cardiovascular disease (control group).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!