Background: Although the efficacy of botulinum toxin type A (BoNTA) has been shown to vary depending on injection layer, reconstitution volume, and BoNTA formulation, the effect of injection pattern has rarely been mentioned. The authors compared the therapeutic effects in patients treated with BoNTA with retrograde linear and traditional spot injection techniques.
Methods: Twenty-eight participants were enrolled in a split-face, patient-blinded randomized clinical trial. Each patient received BoNTA injected with linear injection technique on one side and with spot injection technique on the other side. Outcomes included wrinkle improvement rates (WIRs) of the 2 injection techniques determined by wrinkle scores derived from an Antera 3-dimensional camera, muscle activity assessed by ultrasound, and patient-reported pain rating on a numeric rating scale.
Results: All participants completed the study. For forehead wrinkles, WIR on the linear side was significantly larger than that on the spot side at 1 week and 1 month ( P < 0.02). For glabellar wrinkles, WIR on the linear injection side was significantly larger than that on the spot side at 1 week ( P = 0.04). However, for periorbital wrinkles, WIR on the spot side was significantly larger than that on the linear side at 1 week ( P < 0.03). No significant difference was observed between the injection patterns in terms of muscle contraction and numeric rating scale pain scores.
Conclusions: Compared with the traditional spot injection, retrograde linear injection was superior in reducing forehead lines and glabellar lines, but less effective in reducing periorbital lines when identical dosages were injected.
Clinical Question/level Of Evidence: Therapeutic, II.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/PRS.0000000000010652 | DOI Listing |
Nano Lett
January 2025
State Key Laboratory for Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China.
Anal Bioanal Chem
January 2025
Doping Control Laboratory, Department of Diagnostic Sciences, Ghent University, Block B, Ottergemsesteenweg 460, BE-9000, Ghent, Belgium.
Dried urine spots have recently been proposed as an alternative matrix in the anti-doping field. Drying urine may open the opportunity to limit microbial and thermal degradation of the prohibited substances during transportation to the anti-doping laboratories without the need for refrigeration or freezing. In this study, a multi-targeted initial testing procedure was developed for the determination of 237 prohibited drugs/metabolites from 11 different classes in dried urine spots.
View Article and Find Full Text PDFBiomed Chromatogr
February 2025
Department of Pharmaceutical Analysis, School of Pharmacy, Anurag University, Medchal-Malkajgiri, Hyderabad, Telangana, India.
Paxalisib is a dual PI3K/mTOR inhibitor, being used in advanced cancer treatment. In this research, we report a validated LC-MS/MS method for quantifying paxalisib from mouse dried blood spot (DBS). We validated the method in-line with the FDA guidelines.
View Article and Find Full Text PDFBMC Infect Dis
December 2024
Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province, PR China.
Background: This study aimed to evaluate the diagnostic performance of ESAT6-CFP10 (EC) skin test in healthy population and determine the factors influencing the booster effect.
Methods: We conducted a randomized, double-blind, parallel controlled trial in healthy population. The experiment was divided into two stages.
Int J Neonatal Screen
December 2024
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy NE, S110-3, Atlanta, GA 30341, USA.
Parenteral nutrition (PN) is a nutrient solution administered intravenously (IV) to premature babies. PN causes elevations of some amino acids in blood samples that are also biomarkers used in newborn screening (NBS). Therefore, PN status must be annotated by clinicians on dried blood spot (DBS) cards to reduce NBS laboratory burdens associated with potential false results; however, NBS laboratories continue to receive DBSs with misannotated PN status.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!