Plasma Polishing as a New Polishing Option to Reduce the Surface Roughness of Porous Titanium Alloy for 3D Printing.

J Vis Exp

Orthopedic Center, Affiliated Hospital of Guangdong Medical University; The School of Basic Medical Sciences, Guangdong Medical University; Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University;

Published: April 2023

Porous titanium alloy implants with simulated trabecular bone fabricated by 3D printing technology have broad prospects. However, due to the fact that some powder adheres to the surface of the workpiece during the manufacturing process, the surface roughness in direct printing pieces is relatively high. At the same time, since the internal pores of the porous structure cannot be polished by conventional mechanical polishing, an alternative method needs to be found. As a surface technology, plasma polishing technology is especially suitable for parts with complex shapes that are difficult to polish mechanically. It can effectively remove particles and fine splash residues attached to the surface of 3D printed porous titanium alloy workpieces. Therefore, it can reduce surface roughness. Firstly, titanium alloy powder is used to print the porous structure of the simulated trabecular bone with a metal 3D printer. After printing, heat treatment, removal of the supporting structure, and ultrasonic cleaning is carried out. Then, plasma polishing is performed, consisting of adding a polishing electrolyte with the pH set to 5.7, preheating the machine to 101.6 °C, fixing the workpiece on the polishing fixture, and setting the voltage (313 V), current (59 A), and polishing time (3 min). After polishing, the surface of the porous titanium alloy workpiece is analyzed by a confocal microscope, and the surface roughness is measured. Scanning electron microscopy is used to characterize the surface condition of porous titanium. The results show that the surface roughness of the whole porous titanium alloy workpiece changed from Ra (average roughness) = 126.9 µm to Ra = 56.28 µm, and the surface roughness of the trabecular structure changed from Ra = 42.61 µm to Ra = 26.25 µm. Meanwhile, semi-molten powders and ablative oxide layers are removed, and surface quality is improved.

Download full-text PDF

Source
http://dx.doi.org/10.3791/65108DOI Listing

Publication Analysis

Top Keywords

surface roughness
24
porous titanium
24
titanium alloy
24
plasma polishing
12
surface
12
polishing
8
reduce surface
8
porous
8
roughness porous
8
simulated trabecular
8

Similar Publications

This report investigates the preparation, characterization, and application of activated carbon derived from Spathodea campanulata flowers (SCAC) to remove Congo Red (CR) dye from aqueous streams. SCAC was synthesized using orthophosphoric acid activation which yielded a mesoporous material with a specific surface area of (986.41 m/g), significantly exceeding values reported for flower-derived activated carbons in the available literature.

View Article and Find Full Text PDF

The both-sides machining method can obtain high precision cylindrical rollers, but there is a drawback that the lapping plate is easy to wear, which restricts further improvement in the quality of rollers machining. Aiming to solve this problem, a both-sides machining method using hard ceramic lapping plate is proposed. Friction and wear experiments with different lapping plate materials, along with the corresponding comparative machining experiments, demonstrated the superior performance of AlO ceramic lapping plate in terms of roundness (0.

View Article and Find Full Text PDF

The frozen storage of biopharmaceuticals brings new challenges to the primary packaging material. Due to an increasing demand and the downsides of standard type I glass vials, such as vial breakage, novel vial types for special applications of parenteral drug products have been introduced to the market in the past years. Mechanical stresses due to dimensional changes experienced during freezing and thawing could change the material properties, hence affecting the interaction with the drug product stored in the vial or functionality such as overall integrity.

View Article and Find Full Text PDF

Gelatinase-responsive core-shell nanofiber membranes for anti-adhesion applications.

Int J Biol Macromol

January 2025

MOE Key Laboratory of Advanced Textile Materials & Manufacturing Technology, Zhejiang Sci-Tech University, Hangzhou 310018, China. Electronic address:

Dressings are prone to adhering to new tissues, leading to secondary harm to the wound during dressing replacement. To address this issue, many strategies have been proposed to endow dressings with anti-adhesive functions. However, the introduction of exogenous agents or stimuli is always needed, and difficulty in achieving adaptive removal is also present.

View Article and Find Full Text PDF

This study aimed to establish a microwave-assisted method (MAE) for the efficient extraction of polysaccharides from dandelion roots. This study investigated the molecular structure and bioactivity of the polysaccharides from dandelion roots. Extraction conditions were optimized using response surface methodology (RSM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!