Electrocardiographic (ECG) artifacts may resemble ventricular tachycardia (VT), leading to inappropriate therapies. Despite extensive training, electrophysiologists have still been shown to misinterpret artifacts. The literature is scant regarding the intraoperative identification by anesthesia providers of ECG artifacts resembling VT. We present two cases of the intraoperative occurrence of ECG artifacts resembling VT. The first case involved a patient undergoing extremity surgery after receiving a peripheral nerve block. The patient was treated with a lipid emulsion for a presumptive local anesthetic systemic toxicity diagnosis. The second case was a patient with an implantable cardiac defibrillator (ICD) with suspended anti-tachycardia functionality due to the location of the surgery in the region of the ICD generator. The second case's ECG was identified as an artifact, and no treatment was initiated. Misinterpretation of intraoperative ECG artifacts continues to lead clinicians to institute unnecessary therapies. Our first case occurred in the context of a peripheral nerve block leading to the misdiagnosis of local anesthetic toxicity. The second case occurred during the physical manipulation of the patient during liposuction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168523 | PMC |
http://dx.doi.org/10.7759/cureus.38773 | DOI Listing |
Hum Brain Mapp
December 2024
Graduate School of Information Science and Technology, Osaka University, Osaka, Japan.
Not harming others is widely regarded as a fundamental tenet of human morality. Harm aversion based on the consequences of an action is called utilitarianism while focusing on the action itself is associated with deontology. This study investigated how interoceptive processing affects the neural processing of utilitarian and deontological moral decision-making.
View Article and Find Full Text PDFCureus
November 2024
Department of Cardiovascular Surgery, Tokyo Bay Urayasu Ichikawa Medical Center, Urayasu, JPN.
Contrast-enhanced CT is a primary tool in emergency departments for diagnosing acute aortic dissection, demonstrating high sensitivity and specificity. However, artifacts such as streak artifacts can mimic aortic dissection, leading to misdiagnosis. Here, we report a case involving a 21-year-old male who sustained traumatic injuries after a motor vehicle accident.
View Article and Find Full Text PDFFront Cardiovasc Med
December 2024
Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States.
Purpose: Evaluate the feasibility of quantification of Relaxation Along a Fictitious Field in the 2nd rotating frame (RAFF2) relaxation times in the human myocardium at 3 T.
Methods: mapping was performed using a breath-held ECG-gated acquisition of five images: one without preparation, three preceded by RAFF2 trains of varying duration, and one preceded by a saturation prepulse. Pixel-wise maps were obtained after three-parameter exponential fitting.
Digit Biomark
December 2024
Empatica Srl, Milan, Italy.
Introduction: Though wrist-worn photoplethysmography (PPG) sensors play an important role in long-term and continuous heart rhythm monitoring, signals measured at the wrist are contaminated by more intense motion artifacts compared to other body locations. Machine learning (ML)-based algorithms can improve long-term pulse rate (PR) tracking but are associated with more stringent regulatory requirements when intended for clinical use. This study aimed to evaluate the accuracy of a digital health technology using wrist-worn PPG sensors and an ML-based algorithm to measure PR continuously.
View Article and Find Full Text PDFF1000Res
December 2024
Department of Emergency Medical Services, Sahloul Hospital, Sousse, Tunisia.
Electrocardiograms (ECGs) can be affected by various factors and technical problems. It is rare for an artefact to be the cause of ST-segment elevation, especially in asymptomatic patients. An important distinction between true ST segment elevation caused by myocardial infarction and an artefact is that the baseline elevation in an artefact may begin before or after the appearance of the QRS complex.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!