A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

SmartAct: Energy Efficient and Real-Time Hand-to-Mouth Gesture Detection Using Wearable RGB-T. | LitMetric

SmartAct: Energy Efficient and Real-Time Hand-to-Mouth Gesture Detection Using Wearable RGB-T.

Int Conf Wearable Implant Body Sens Netw

Department of Computer Science, Department of Preventive Medicine, Northwestern University, Evanston, IL, USA.

Published: September 2022

Researchers have been leveraging wearable cameras to both visually confirm and automatically detect individuals' eating habits. However, energy-intensive tasks such as continuously collecting and storing RGB images in memory, or running algorithms in real-time to automate detection of eating, greatly impacts battery life. Since eating moments are spread sparsely throughout the day, battery life can be mitigated by recording and processing data only when there is a high likelihood of eating. We present a framework comprising a golf-ball sized wearable device using a low-powered thermal sensor array and real-time activation algorithm that activates high-energy tasks when a hand-to-mouth gesture is confirmed by the thermal sensor array. The high-energy tasks tested are turning on the RGB camera (Trigger RGB mode) and running inference on an on-device machine learning model (Trigger ML mode). Our experimental setup involved the design of a wearable camera, 6 participants collecting 18 hours of data with and without eating, the implementation of a feeding gesture detection algorithm on-device, and measures of power saving using our activation method. Our activation algorithm demonstrates an average of at-least 31.5% increase in battery life time, with minimal drop of recall (5%) and without impacting the accuracy of detecting eating (a slight 4.1% increase in F1-Score).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10176499PMC
http://dx.doi.org/10.1109/bsn56160.2022.9928492DOI Listing

Publication Analysis

Top Keywords

battery life
12
hand-to-mouth gesture
8
gesture detection
8
thermal sensor
8
sensor array
8
activation algorithm
8
high-energy tasks
8
eating
6
smartact energy
4
energy efficient
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!