Objective: There is a lack of data regarding the long-term clinical efficacy of the kissing balloon inflation (KBI) after provisional stenting of coronary bifurcation lesions. The aim of this study was to analyze the impact of KBI on long-term clinical outcomes in patients undergoing provisional stenting for the coronary bifurcation lesions in a large real-world population.

Methods: A total of 873 patients who underwent percutaneous coronary interventions (PCI) with provisional stenting and had clinical follow up were analyzed. Patients treated with 2-stent strategy were excluded. To reduce the effect of potential confounding factors in this observational study, propensity score matching was conducted.

Results: KBI was performed in 325 patients (37.2%). The median follow-up duration was 37.3 months. Patients treated with KBI more often had a previous PCI (48.6% vs. 42.5% SMD = 0.123). Patients in non-kissing group had more complex coronary disease with higher prevalence of calcification (14.8% vs. 21.4% SMD = 0.172), thrombosis (2.8% vs. 5.8% SMD = 0.152) and longer side branch lesions (8.3% vs. 11.7% SMD = 0.113). There were no significant differences in the major adverse cardiac events including death, myocardial infarction, target lesion revascularization after KBI versus no KBI (15.4% vs. 15.7%, p = 0.28), in total cohort or in matched patients (17.1% vs. 15.8%, adjusted HR 1.01, 95% CI: 0.65-1.65, p = 0.95). The lack of effect of KBI on clinical outcomes was consistent across various subgroups including left main disease.

Conclusion: In this multicenter real-world registry, KBI did not improve long-term clinical outcomes in patients with coronary bifurcation lesions treated with provisional stenting technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10568054PMC
http://dx.doi.org/10.1016/j.ihj.2023.05.003DOI Listing

Publication Analysis

Top Keywords

provisional stenting
20
long-term clinical
16
clinical outcomes
16
coronary bifurcation
16
bifurcation lesions
16
patients
9
kissing balloon
8
balloon inflation
8
patients coronary
8
lesions treated
8

Similar Publications

Background: Jailed wire (JW) in the side branch (SB) is recommended during coronary bifurcation provisional stenting, but real benefit is unsure. Our objective was to evaluate benefit of a JW technique in the CABRIOLET registry.

Methods: In CABRIOLET, including 500 patients, we compared the primary composite endpoint poor final SB angiographic result (TIMI flowB, thrombosis, residual stenosis>70%, or additional SB stenting) whether JW was performed or not.

View Article and Find Full Text PDF

Decoding medina 0.0.1 bifurcation: Are all codes equal? Results from a multicentric registry.

Int J Cardiol

November 2024

Institut Cardiovasculaire Paris Sud, Ramsay Générale de Santé, Massy, France. Electronic address:

Objectives: This study aimed to detail the technical management of Medina 0.0.1 lesions, assess their outcomes, and identify predictors of Major Adverse Cardiovascular Events (MACE).

View Article and Find Full Text PDF

Impact of intravascular ultrasound for coronary bifurcations treated with last generations stents: insights from the BIFURCAT-ULTRA registry.

Eur Heart J Qual Care Clin Outcomes

November 2024

Division of Cardiology, Cardiovascular and Thoracic Department, A.O.U Città della Salute e della Scienza, Turin, Italy.

Background: Bifurcation lesions are associated with higher rates of major adverse cardiovascular events (MACE).

Aim: To investigate the impact of imaging-guided PCI in a real-world population with coronary bifurcation lesions.

Methods: From the ULTRA-BIFURCAT registry, we compared IVUS vs.

View Article and Find Full Text PDF

Continuously monitoring human airway conditions is crucial for timely interventions, especially when airway stents are implanted to alleviate central airway obstruction in lung cancer and other diseases. Mucus conditions, in particular, are important biomarkers for indicating inflammation and stent patency but remain challenging to monitor. Current methods, reliant on computational tomography imaging and bronchoscope inspection, pose risks due to radiation and lack the ability to provide continuous real-time feedback outside of hospitals.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigated the effectiveness of drug-coated balloons (DCB) versus noncompliant balloons (NCB) for treating compromised side branches during provisional stenting in coronary bifurcations.
  • A total of 784 patients with significant stenosis were randomly assigned to either DCB or NCB, with follow-up focusing on major adverse cardiac events over one year.
  • Results showed that patients using DCB experienced significantly fewer major events (7.2%) compared to those using NCB (12.5%), highlighting a potential advantage of DCB in these cases.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!