Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The flexibility of NiTi based endodontic files is improved by heat treatment, leading to lower risk of failure, ledges, and canal transportation during the preparation of curved root canals. The aim of this study is to investigate and clearly highlight the influence of every parameter of heat treatment on the flexibility of NiTi wires and thus of endodontic instruments. A full factorial Design of Experiment (DoE) and a designed bending-torsion bench following the ISO 3630-1 standard were used for this investigation. Temperature, holding time, and cooling method were selected as contributing factors, while maximum bending moment, hysteresis size, and stiffness during martensitic transformation were selected as outputs. Regression analysis was performed to estimate the relationship between contributing and output variables to assess how the experimentation fits with the model. The experimental results showed that wires heated at 425 °C for 30 min are more flexible. Moreover, heat treatment temperature is the most critical factor influencing the flexibility and hysteresis size of the NiTi wire followed by the holding time, while the cooling method has a negligible effect. The regression analysis showed that the model is effective at predicting the relationship between contributing factors, bending moment response, and hysteresis size.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10180458 | PMC |
http://dx.doi.org/10.3390/ma16093437 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!