A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a non-targeted method devoted to identification and quantitation of toxicologically relevant compounds in plasma with HRMS. | LitMetric

Validation of a non-targeted method devoted to identification and quantitation of toxicologically relevant compounds in plasma with HRMS.

J Chromatogr B Analyt Technol Biomed Life Sci

Laboratory of Pharmacokinetics and Toxicology, La Timone University Hospital, 264, rue Saint Pierre, 13385 Marseille Cedex 5, France; Aix Marseille University, INSERM, IRD, SESSTIM, Economic and Social Sciences of Health and Medical Information Processing, 27 Bd Jean Moulin, 13385 Marseille, France. Electronic address:

Published: May 2023

The objective of this study was to develop and validate a simple method using liquid chromatography hyphenated to high resolution mass spectrometry (HRMS) allowing both the performance of a non-targeted screening and the simultaneous quantification of 29 compounds of interest in clinical and forensic toxicology. Extraction was done with QuEChERS salts and acetonitrile, after addition of internal standard to 200 μL of human plasma samples. The mass spectrometer was an Orbitrap, with a heated electrospray ionization (HESI) probe. The analyses were carried out in full scan experiment with a nominal resolving power of 60,000 FWHM within the 125-650 m/z mass range, followed by four cycles of data dependent analysis (DDA) with a mass resolution of 16,000 FWHM. The untargeted screening was evaluated using 132 compounds, mean limit of identification (LOI) was 8.8 ng/mL (min = 0.05 ng/mL, max = 500 ng/mL) and mean limit of detection (LOD) was 0.25 ng/mL (min = 0.05 ng/mL, max = 5 ng/mL). The method was linear in the 5 to 500 ng/mL range (0.5 to 50 ng/mL for cannabinoids, 6-acetylmorphine and buprenorphine) with correlation coefficients > 0.99, intra- and inter-day accuracy and precision were < 15% for all compounds. The method was successfully applied to 31 routine samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2023.123739DOI Listing

Publication Analysis

Top Keywords

validation non-targeted
4
non-targeted method
4
method devoted
4
devoted identification
4
identification quantitation
4
quantitation toxicologically
4
toxicologically relevant
4
relevant compounds
4
compounds plasma
4
plasma hrms
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!