Introduction: Fetal electrocardiography (NI-fECG) and electrohysterography (EHG) have been proven more accurate and reliable than conventional non-invasive methods (doppler ultrasound and tocodynamometry) and are less affected by maternal obesity. It is still unknown whether NI-fECG and EHG will eliminate the need for invasive methods, such as the intrauterine pressure catheter and fetal scalp electrode. We studied whether NI-fECG and EHG can be successfully used during labor.

Material And Methods: A prospective clinical pilot study was performed in a tertiary care teaching hospital. A total of 50 women were included with a singleton pregnancy with a gestational age between 36 and 42  weeks and had an indication for continuous intrapartum monitoring. The primary study outcome was the percentage of women with NI-fECG and EHG monitoring throughout the whole delivery. Secondary study outcomes were reason and timing of a switch to conventional monitoring methods (i.e., tocodynamometry and fetal scalp electrode or doppler ultrasound), repositioning of the abdominal electrode patch, success rates (i.e., the percentage of time with signal output), and obstetric and neonatal outcomes.

Clinical Trial Registration: Dutch trial register (NL8024).

Results: In 45 women (90%), NI-fECG and EHG monitoring was used throughout the whole delivery. In the other five women (10%), there was a switch to conventional methods: in two women because of insufficient registration quality of uterine contractions and in three women because of insufficient registration quality of the fetal heart rate. In three out of five cases, the switch was after full dilation was reached. Repositioning of the abdominal electrode patch occurred in two women. The overall success rate was 94.5%. In 16% (n = 8) of women, a cesarean delivery was performed due to non-progressing dilation (n = 7) and due to suspicion of fetal distress (n = 1). Neonatal metabolic acidosis did not occur. Two neonates (4%) were admitted to the neonatal intensive care unit for complications not related to intrapartum monitoring.

Conclusions: NI-fECG and EHG can be successfully used during labor in 90% of women. Future research is needed to conclude whether implementation of electrophysiological monitoring can improve obstetric and neonatal outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10333653PMC
http://dx.doi.org/10.1111/aogs.14571DOI Listing

Publication Analysis

Top Keywords

ni-fecg ehg
20
women
9
fetal electrocardiography
8
prospective clinical
8
doppler ultrasound
8
fetal scalp
8
scalp electrode
8
ehg monitoring
8
monitoring delivery
8
switch conventional
8

Similar Publications

Introduction: Fetal electrocardiography (NI-fECG) and electrohysterography (EHG) have been proven more accurate and reliable than conventional non-invasive methods (doppler ultrasound and tocodynamometry) and are less affected by maternal obesity. It is still unknown whether NI-fECG and EHG will eliminate the need for invasive methods, such as the intrauterine pressure catheter and fetal scalp electrode. We studied whether NI-fECG and EHG can be successfully used during labor.

View Article and Find Full Text PDF

Background: Worldwide, hypertensive disorders of pregnancy (HDP), fetal growth restriction (FGR) and preterm birth remain the leading causes of maternal and fetal pregnancy-related mortality and (long-term) morbidity. Fetal cardiac deformation changes can be the first sign of placental dysfunction, which is associated with HDP, FGR and preterm birth. In addition, preterm birth is likely associated with changes in electrical activity across the uterine muscle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!