Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Clinical outcomes are normally captured less frequently than data from remote technologies, leaving a disparity in volumes of data from these different sources. To align these data, flexible polynomial regression was investigated to estimate personalised trends for a continuous outcome over time.
Methods: Using electronic health records, flexible polynomial regression models inclusive of a 1st up to a 4th order were calculated to predict forced expiratory volume in 1 s (FEV) over time in children with cystic fibrosis. The model with the lowest AIC for each individual was selected as the best fit. The optimal parameters for using flexible polynomials were investigated by comparing the measured FEV values to the values given by the individualised polynomial.
Results: There were 8,549 FEV measurements from 267 individuals. For individuals with > 15 measurements (n = 178), the polynomial predictions worked well; however, with < 15 measurements (n = 89), the polynomial models were conditional on the number of measurements and time between measurements. The method was validated using BMI in the same population of children.
Conclusion: Flexible polynomials can be used to extrapolate clinical outcome measures at frequent time intervals to align with daily data captured through remote technologies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10176913 | PMC |
http://dx.doi.org/10.1186/s12874-023-01942-4 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!