Objectives: Current evidence on transcatheter aortic valve implantation (TAVI) has been generated exclusively by cardiology studies and no operative data from cardiac surgeons are available. Here, we describe the development of our TAVI programme and report the results of transfemoral (TF) TAVI done by cardiac surgeons on their own.

Methods: This study included all the TAVI procedures on native valve performed at Cardiac Surgery Unit, Ospedali Riuniti di Ancona, during the period October 2018 to July 2022. Relevant prospectively collected preoperative, intraprocedural and postoperative data were retrieved from the Institutional database.

Results: A total of 413 patients were included in the study. Mean patients' age was 82 years and among them 44% (180/413) were male. STS score was 3.1% (2.2-4.4). Eighty patients underwent transapical TAVI and 333 patients had a TF approach. We progressively moved from transapical TAVI towards TF procedures that are now routinely performed on conscious sedation and using a fully percutaneous approach. After TF TAVI, 30-day mortality rate was 1%, cerebral stroke occurred in 2% of the cases, permanent pacemaker implantation was necessary in 23% of the patients and in 6% of the cases there was a moderate/severe degree of aortic regurgitation. There was no association between operators performing TAVI and 30-day mortality.

Conclusions: The acquisition of catheter-based skills and an adequate training allowed cardiac surgeons to perform on their own awake and fully percutaneous TF TAVI with similar results when compared with major randomized clinical trials and registries' experiences.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10243841PMC
http://dx.doi.org/10.1093/icvts/ivad074DOI Listing

Publication Analysis

Top Keywords

cardiac surgeons
16
tavi procedures
12
tavi
10
performed cardiac
8
transapical tavi
8
fully percutaneous
8
tavi 30-day
8
cardiac
5
insights 413
4
413 tavi
4

Similar Publications

Off-Pump Coronary Artery Bypass Grafting is Overutilized.

Semin Thorac Cardiovasc Surg

December 2024

Department of Cardiac Surgery, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA 90048. Electronic address:

Off-pump coronary artery bypass grafting (CABG), developed to avoid the potential complications of cardiopulmonary bypass, remains a subject of debate. Studies have demonstrated that off-pump CABG is associated with higher rates of incomplete revascularization, inferior graft patency, and increased reintervention rates compared to on-pump CABG, leading to worse outcomes. The theoretical neuroprotective and renal-protective benefits associated with off-pump CABG have not been definitively proven, with stroke and renal failure rates similar to those of on-pump CABG in both short- and long-term follow-up.

View Article and Find Full Text PDF

Three-dimensional (3D) printing is an advanced technology for accurately understanding anatomy and supporting the successful surgical management of complex congenital heart disease (CHD). We aimed to evaluate whether our super-flexible 3D heart models could facilitate preoperative decision-making and surgical simulation for complex CHD. The super-flexible heart models were fabricated by stereolithography 3D printing of the internal and external contours of the heart from cardiac computed tomography (CT) data, followed by vacuum casting with a polyurethane material similar in elasticity to a child's heart.

View Article and Find Full Text PDF

Background: Traditional decannulation of femoral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) involves femoral cutdown. Percutaneous methods have been developed, but data supporting their use is limited. We sought to compare the MANTA vascular closure device to open decannulation.

View Article and Find Full Text PDF

Background: We sought to identify predictors of acute renal failure (ARF) following acute type A aortic dissection (ATAAD) and its implications on postoperative outcomes.

Methods: ATAAD cases were identified from The Society of Thoracic Surgeons - Adult Cardiac Surgery Database (2017-2022). Cases with chronic dissection, prior aortic repair, primary endovascular repair, preoperative extracorporeal membrane oxygenation, preoperative renal failure, and operative room deaths were excluded.

View Article and Find Full Text PDF

A Case Report Describing the Surgical Removal of Venous and Intracardiac Cement Leakage after Percutaneous Vertebroplasty in a Hybrid Operating Room.

Ann Ital Chir

December 2024

Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy; Department of Biomedical, Surgical, and Dental Sciences, University of Milan, 20122 Milan, Italy.

Aim: Percutaneous vertebroplasty is generally considered a safe procedure, however, cases of cardioembolism and cardiac perforation have been reported.

Case Presentation: A 69-year-old woman was referred to our emergency department after an outpatient echocardiogram revealed a "thrombus-like" formation involving the right heart. Two weeks before she had undergone percutaneous vertebroplasty of the third to fifth lumbar vertebrae due to osteoporotic fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!