In electric field modified flames, the electric body force on fluid elements can play a role in modifying the flow field, affecting flame characteristics by this modified flow motion. Numerical studies have developed ion kinetic mechanisms and appropriate transport models for charged species, validating them with a voltage-current trend in 1D premixed flames. Recent experimental approaches have measured the electric field by adopting the Electric Field Induced Second Harmonic generation (EFISH) technique. However, the quantification has turned out very challenging due to the inherent distortion in the EFISH signal, as well as inhomogeneous temperature and concentration fields in the combustion field. Here, we propose measurement and calibration schemes to quantify the EFISH signal in a laminar counterflow nonpremixed flame and present comparison with numerical results using an in-house multi-physics CFD (Computational Fluid Dynamics) code. Overall, the quantified electric fields agreed well with those from numerical simulation, specifically capturing null electric fields near the flame in the sub-saturated regime due to the electric field screening effect. In the saturated regime, notable discrepancy was found in a fuel stream when electrons moved through it: experiment indicated a significant number of negative ions in the fuel stream, whereas numerical results predicted negligible negative ions, due to the implemented ion-mechanism. This suggested that the experimentally obtained electric fields may serve as validation data for modeling studies to improve transport models and ion-mechanism. In-situ measurement of charged species in the presence of external electric fields should be a future work.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172352PMC
http://dx.doi.org/10.1038/s41598-023-34769-6DOI Listing

Publication Analysis

Top Keywords

electric fields
20
electric field
16
electric
10
counterflow nonpremixed
8
nonpremixed flame
8
transport models
8
charged species
8
efish signal
8
fuel stream
8
negative ions
8

Similar Publications

Evidence for a metal-bosonic insulator-superconductor transition in compressed sulfur.

Proc Natl Acad Sci U S A

January 2025

State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China.

The abrupt drop of resistance to zero at a critical temperature is a key signature of the current paradigm of the metal-superconductor transition. However, the emergence of an intermediate bosonic insulating state characterized by a resistance peak preceding the onset of the superconducting transition has challenged this traditional understanding. Notably, this phenomenon has been predominantly observed in disordered or chemically doped low-dimensional systems, raising intriguing questions about the generality of the effect and its underlying fundamental physics.

View Article and Find Full Text PDF

Dual-Anion-Rich Polymer Electrolytes for High-Voltage Solid-State Lithium Metal Batteries.

ACS Nano

January 2025

Department of Physics, JC STEM Lab of Energy and Materials Physics, City University of Hong Kong, Hong Kong 999077, P. R. China.

Solid polymer electrolytes (SPEs) are promising candidates for lithium metal batteries (LMBs) owing to their safety features and compatibility with lithium metal anodes. However, the inferior ionic conductivity and electrochemical stability of SPEs hinder their application in high-voltage solid-state LMBs (HVSSLMBs). Here, a strategy is proposed to develop a dual-anion-rich solvation structure by implementing ferroelectric barium titanate (BTO) nanoparticles (NPs) and dual lithium salts into poly(vinylidene fluoride) (PVDF)-based SPEs for HVSSLMBs.

View Article and Find Full Text PDF

Detection of Extracochlear Electrodes Using Electrical Field Imaging (EFI).

Otol Neurotol

February 2025

Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.

Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).

Study Design: Retrospective cohort study.

Setting: Tertiary academic medical center.

View Article and Find Full Text PDF

Heterojunctions, known for their decent separation of photo-generated electrons and holes, are promising for photocatalytic CO reduction. However, a significant obstacle in traditional post-assembled heterojunctions is the high interfacial barrier for charge transfer caused by atomic lattice mismatch at multiphase interfaces. Here, as research prototypes, the study creates a lattice-matched co-atomic interface within CsPbBr-CsPbBr polytypic nanocrystals (113-125 PNs) through the proposed in situ hybrid strategy to elucidate the underlying charge transfer mechanism within this unique interface.

View Article and Find Full Text PDF

Precise Sizing and Collision Detection of Functional Nanoparticles by Deep Learning Empowered Plasmonic Microscopy.

Adv Sci (Weinh)

January 2025

Department of Chemistry, Center for BioAnalytical Chemistry, Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology, Tsinghua University, Beijing, 100084, China.

Single nanoparticle analysis is crucial for various applications in biology, materials, and energy. However, precisely profiling and monitoring weakly scattering nanoparticles remains challenging. Here, it is demonstrated that deep learning-empowered plasmonic microscopy (Deep-SM) enables precise sizing and collision detection of functional chemical and biological nanoparticles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!