Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide.
Methods/findings: In our ongoing USA feasibility/efficacy clinical trial, data collated with other ongoing and earlier published results proved high performance of an Immunochromatographic-test(ICT) that enables accurate, rapid diagnosis/treatment, establishing new paradigms for care. Overall results from patient blood and/or serum samples tested with ICT compared with gold-standard-predicate-test results found ICT performance for 4606 sera/1876 blood, 99.3%/97.5% sensitive and 98.9%/99.7% specific. However, in the clinical trial the FDA-cleared-predicate test initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO ASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening.
Conclusions/significance: This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories.
Author’s Summary: Toxoplasmosis is a major health burden for developed and developing countries, causing damage to eyes and brain, loss of life and substantial societal costs. Prompt diagnosis in gestational screening programs enables treatment, thereby relieving suffering, and leading to > 14-fold cost savings for care. Herein, we demonstrate that using an ICT that meets WHO ASSURED-criteria identifying persons with/without antibody to in sera and whole blood with high sensitivity and specificity, is feasible to use in USA clinical practice. We find this new approach can help to obviate the problem of detection of false positive anti- IgM results for those without IgG antibodies to when this occurs in present, standard of care, predicate USA FDA cleared available assays. Thus, this accurate test facilitates gestational screening programs and a global initiative to diagnose and thereby prevent and treat infection. This minimizes likelihood of false positives (IgG and/or IgM) while maintaining maximum sensitivity. When isolated IgM antibodies are detected, it is necessary to confirm and when indicated continue follow up testing in ∼2 weeks to establish seroconversion. Presence of a positive ICT makes it likely that IgM is truly positive and a negative ICT makes it likely that IgM will be a false positive without infection. These results create a new, enthusiastically-accepted, precise paradigm for rapid diagnosis and validation of results with a second-line test. This helps eliminate alarm and anxiety about false-positive results, while expediting needed treatment for true positive results and providing back up distinguishing false positive tests.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168490 | PMC |
http://dx.doi.org/10.1101/2023.04.26.23289132 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!