Background: The organisms causing penile implant infections are changing from predominantly indolent gram-positive infections to more aggressive gram-negative and fungal infections because of antibiotic selection pressures based on novel next-generation sequencing DNA data.

Aim: To evaluate the effectiveness of Irrisept solution (0.05% chlorhexidine gluconate) in decreasing isolate colony counts from a Titan implant by using a novel kill time washout methodology to mirror real-world usage.

Methods: Sterilized Titan discs were dipped in Irrisept or saline. An inoculum of 109 organisms of a single bacterial or fungal species was placed on the discs. Bacterial and fungal strains were tested: Bacteroides fragilis, Candida albicans, Enterococcus faecalis, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and Staphylococcus epidermidis. The discs were then irrigated 3 times with Irrisept or saline. Microorganisms were sonicated off the discs and placed on appropriate agar and conditions for each species. The plates were incubated for 48 to 72 hours at the temperature and under the conditions appropriate for each species. Colonies on the plates were hand counted.

Outcomes: Irrisept effectively decreased microbial colony counts in all the species tested.

Results: Irrisept was shown to effectively decrease microbial colony counts from 3 to 6 log10 in all species tested. A 3-log10 reduction is considered the target level of performance that would indicate that a compound or product has effective killing activity against an organism of interest. The saline control with bulb syringe irrigation did not demonstrate reduction of microbial colony counts in any of the species tested.

Clinical Implications: Irrisept is effective against all of the organisms causing modern-day infections with penile implant surgery and may decrease clinical infection rates to lower levels.

Strengths And Limitations: The strength of this study is that we used quantitative microbial reduction counting and the largest array of bacterial and fungal species causing modern-day penile implant infections. The limitation is that this is an in vitro study and the clinical implications of our findings are not yet known.

Conclusion: Quantitative microbial reduction counting shows that Irrisept is effective against the most commonly known modern-day organisms causing penile implant infections.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jsxmed/qdad055DOI Listing

Publication Analysis

Top Keywords

penile implant
16
colony counts
16
fungal species
12
organisms causing
12
implant infections
12
bacterial fungal
12
microbial colony
12
irrisept
8
irrisept solution
8
solution 005%
8

Similar Publications

: Artificial intelligence (AI), particularly natural language processing (NLP) models such as ChatGPT, presents novel opportunities for patient education and informed consent. This study evaluated ChatGPT's use as a support tool for informed consent before penile prosthesis implantation (PPI) in patients with erectile dysfunction (ED) following radical prostatectomy. : ChatGPT-4 answered 20 frequently asked questions across four categories: ED and treatment, PPI surgery, complications, and postoperative care.

View Article and Find Full Text PDF

Insertion of inflatable penile prosthesis (IPP) is generally regarded as a safe procedure, with low rates of complications. However, when complications do arise, they can pose significant challenges to both patients and surgeons. Patient optimization and adherence to specific intraoperative protocols are crucial in mitigating the risk of surgical complications.

View Article and Find Full Text PDF

Penile prosthesis (PP) implantation is feasible as an outpatient surgery. The present study describes the surgical process and establishes a consensus for improving the care circuit for outpatient PP implantation in Spain. A working group composed of a scientific committee with extensive experience in PP implantation and representatives of important scientific societies reached a consensus about the recommendations for outpatient PP implantation.

View Article and Find Full Text PDF

Penile Reconstruction with Radial Forearm Free Flap-Present State of the Art.

Indian J Plast Surg

December 2024

Department of Plastic and Reconstructive Surgery, Amrita Hospital, Faridabad, Haryana, India.

Article Synopsis
  • Patients with penile defects, whether congenital or acquired, experience significant psychological distress, and the free radial artery forearm flap method has emerged as a preferred technique for reconstruction.
  • A retrospective study over 16 years reviewed various cases, modifying the initial design to enhance urethral function and stability in the procedure.
  • Results indicated that most patients regained sensation and could urinate standing; however, some experienced complications, and aesthetic outcomes varied, highlighting the technique's potential for effective rehabilitation.
View Article and Find Full Text PDF

Implantation of inflatable penile prosthesis should be considered as a definitive treatment of erectile dysfunction. However, the sole procedure might not allow for optimal dimensional and functional outcomes. The aim of this study was to systematically review the literature and present the findings on the optimal choice of perioperative methods, surgical techniques, and pharmacotherapy to improve penile length, curvature, and erectile function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!