Low-loss photonic integrated circuits (PICs) are the key elements in future quantum technologies, nonlinear photonics and neural networks. The low-loss photonic circuits technology targeting C-band application is well established across multi-project wafer (MPW) fabs, whereas near-infrared (NIR) PICs suitable for the state-of-the-art single-photon sources are still underdeveloped. Here, we report the labs-scale process optimization and optical characterization of low-loss tunable photonic integrated circuits for single-photon applications. We demonstrate the lowest propagation losses to the date (as low as 0.55 dB/cm at 925 nm wavelength) in single-mode silicon nitride submicron waveguides (220×550 nm). This performance is achieved due to advanced e-beam lithography and inductively coupled plasma reactive ion etching steps which yields waveguides vertical sidewalls with down to 0.85 nm sidewall roughness. These results provide a chip-scale low-loss PIC platform that could be even further improved with high quality SiO cladding, chemical-mechanical polishing and multistep annealing for extra-strict single-photon applications.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.477458DOI Listing

Publication Analysis

Top Keywords

silicon nitride
8
low-loss photonic
8
photonic integrated
8
integrated circuits
8
single-photon applications
8
low-loss
5
low-loss silicon
4
photonic
4
nitride photonic
4
photonic ics
4

Similar Publications

In situ electrochemical liquid phase transmission electron microscopy (LP-TEM) measurements utilize micro-chip three-electrode cells with electron transparent silicon nitride windows that confine the liquid electrolyte. By imaging electrocatalysts deposited on micro-patterned electrodes, LP-TEM provides insight into morphological, phase structure, and compositional changes within electrocatalyst materials under electrochemical reaction conditions, which have practical implications on activity, selectivity, and durability. Despite LP-TEM capabilities becoming more accessible, in situ measurements under electrochemical reaction conditions remain non-trivial, with challenges including electron beam interactions with the electrolyte and electrode, the lack of well-defined experimental workflows, and difficulty interpreting particle behavior within a liquid.

View Article and Find Full Text PDF

Azo-PMA nanopores of sub-20 nm length for unimolecular resolution of nucleic acids and proteins.

Talanta

December 2024

Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences & Chongqing School, University of Chinese Academy of Science, Chongqing, 400714, PR China. Electronic address:

Owing to the facile fabrication and surface modification, the cost-effective polymer nanopores are widely employed in unimolecular determination of biomacromolecules and selective sensing of small molecules, nanoparticles and biomarkers. However, the documented polymer nanochannels are generally microscale in length with low spatial resolution. We herein synthesized azobenzene side-chain polymer (Azo-PMA) and spin-coated on silicon nitride membrane to obtain a polymer film of nanoscale thickness for further nanopore generation via controlled dielectric breakdown (CDB) approach.

View Article and Find Full Text PDF

3DCryoHolder: a new open access 3D printable system to store and transport silicon nitride membranes under cryogenic conditions for spectromicroscopy at low temperature.

J Synchrotron Radiat

January 2025

Polimero eta Material Aurreratuak: Fisika, Kimika eta Teknologia, Kimika Fakultatea, Euskal Herriko Unibertsitatea UPV/EHU, Donostia-San Sebastian 20018, Spain.

Data acquisition under cryogenic conditions allows one to avoid unwanted damage caused by beam irradiation. This is particularly important for the study of biological samples at hard X-ray, micro- or nano-probe beamlines, which focus synchrotron radiation to small beam sizes with extremely high flux densities. Sample preparation methods for cryopreserved specimens have been adapted from electron microscopy, and include the use of silicon nitride membranes as they are easy to handle and possess low X-ray absorption.

View Article and Find Full Text PDF

Single-molecule fluorescence spectroscopy offers unique capabilities for the low-concentration sensing and probing of molecular dynmics. However, employing such a methodology for versatile sensing and diagnostics under point-of-care demands device miniaturization to lab-on-a-chip size. In this study, we numerically design metalenses with high numerical aperture (NA = 1.

View Article and Find Full Text PDF

Advances, Challenges, and Applications of Graphene and Carbon Nanotube-Reinforced Engineering Ceramics.

Nanomaterials (Basel)

November 2024

Institute for Technical Physics and Materials Science, HUN-REN Centre for Energy Research, Konkoly-Thege Miklós Str. 29-33, 1121 Budapest, Hungary.

Engineering ceramics and their composites are widely used owing to their excellent properties, including high wear, corrosion and heat resistance, low friction coefficient, and low thermal conductivity; thus, the current paper presents a comprehensive review of the most common types of engineering ceramics, demonstrating their key properties, advantages, potential applications, and challenges. This paper also provides prevailing methods for tackling the engineering ceramic challenges and maximizing their applicability. This review paper focuses on alumina (AlO), silicon carbide (SiC), zirconia (ZrO), aluminum nitride (AlN), and silicon nitride (SiN), and explores their usability in automotive, aerospace, and tribological applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!