Brillouin microscopy has recently emerged as a powerful tool for mechanical property measurements in biomedical sensing and imaging applications. Impulsive stimulated Brillouin scattering (ISBS) microscopy has been proposed for faster and more accurate measurements, which do not rely on stable narrow-band lasers and thermally-drifting etalon-based spectrometers. However, the spectral resolution of ISBS-based signal has not been significantly explored. In this report, the ISBS spectral profile has been investigated as a function of the pump beam's spatial geometry, and novel methodologies have been developed for accurate spectral assessment. The ISBS linewidth was found to consistently decrease with increasing pump-beam diameter. These findings provide the means for improved spectral resolution measurements and pave the way to broader applications of ISBS microscopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10316680 | PMC |
http://dx.doi.org/10.1364/OE.487131 | DOI Listing |
Sci Rep
January 2025
Department of Ophthalmology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.
To describe the management and clinical course of 12 cases of pseudophakic aqueous misdirection syndrome (AMS). Twelve eyes of 12 Patients diagnosed with pseudophakic AMS between 2021 and 2022 were included. Best-corrected visual acuity, refraction, intraocular pressure (IOP), anti-glaucomatous medication, spectral domain ocular coherence tomography (SD-OCT) and postoperative complications were evaluated.
View Article and Find Full Text PDFSci Total Environ
January 2025
Marine Toxicology, Institute of Marine Research, Bergen, Norway.
Polycyclic aromatic hydrocarbons (PAHs) are toxic contaminants with a widespread presence in diverse environmental contexts. Transformation processes of PAHs via degradation and biotransformation have parallels in humans, animals, plants, fungi, and bacteria. Mapping the transformation products of PAHs is therefore crucial for assessing their toxicological impact and developing effective monitoring strategies.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, DK-1871, Frederiksberg, Denmark.
Liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) is commonly used for identification of compounds in complex samples due to the high chromatographic and mass spectral resolution provided. In subsequent data processing workflows, it is imperative to preserve this resolution to fully exploit the data. "Region of interest" (ROI) algorithms were introduced as a better alternative to equidistant binning for compressing HRMS data because they better preserve the mass spectral resolution.
View Article and Find Full Text PDFNMR Biomed
February 2025
MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland.
The purpose of this study was to produce metabolite-specific T and concentration maps in a clinically compatible time frame. A multi-TE 2D MR spectroscopic imaging (MRSI) experiment (multi-echo single-shot MRSI [MESS-MRSI]) deployed truncated and partially sampled multi-echo trains from single scans and was combined with simultaneous multiparametric model fitting. It was tested in vivo for the brain in five healthy subjects.
View Article and Find Full Text PDFAnal Chem
January 2025
Laboratory for Air Pollution/Environmental Technology, Empa, 8600 Dübendorf, Switzerland.
Mid-infrared laser absorption spectroscopy enables rapid and nondestructive analysis of methane clumped isotopes. However, current analytical methods require a sample size of 20 mL STP (0.82 mmol) of pure CH gas, which significantly limits its application to natural samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!