We propose a numerical and automatic quadratic phase aberration elimination method in digital holography for phase-contrast imaging. A histogram segmentation method based on Gaussian 1σ-criterion is used to obtain the accurate coefficients of quadratic aberrations using the weighted least-squares algorithm. This method needs no manual intervention for specimen-free zone or prior parameters of optical components. We also propose a maximum-minimum-average-standard deviation (MMASD) metric to quantitatively evaluate the effectiveness of quadratic aberration elimination. Simulation and experimental results are demonstrated to verify the efficacy of our proposed method over the traditional least-squares algorithm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.486890DOI Listing

Publication Analysis

Top Keywords

digital holography
8
based gaussian
8
histogram segmentation
8
aberration elimination
8
least-squares algorithm
8
automatic elimination
4
elimination phase
4
phase aberrations
4
aberrations digital
4
holography based
4

Similar Publications

We recently demonstrated polarisation differential phase contrast microscopy () as a robust, low-cost single-shot implementation of (semi)quantitative phase imaging based on differential phase microscopy. utilises a polarisation-sensitive camera to simultaneously acquire four obliquely transilluminated images from which phase images mapping spatial variation of optical path difference can be calculated. microscopy can be implemented on existing or bespoke microscopes and can utilise radiation at a wide range of visible to near infrared wavelengths and so is straightforward to integrate with fluorescence microscopy.

View Article and Find Full Text PDF

Background And Purpose: Quantitative MRI (qMRI) has been explored for detecting tumor changes during radiation therapy (RT) in head and neck squamous cell cancer (HNSCC). Clinical trials show prolonged survival with PD-1 targeted immune checkpoint inhibition. Hypofractionated radiation regimens are being studied to counteract radioresistant clonogen formation.

View Article and Find Full Text PDF

Traditional numerical reconstruction methods in digital holography (DH) are faced with problems such as inaccurate and time-consuming unwrapping or the need to capture multiple holograms with different diffraction distances. In recent years, deep learning, believed to be a new and effective optimization tool, has been widely used in digital holography. However, most supervised deep learning methods require large-scale paired data, and their preparation is time-consuming and laborious.

View Article and Find Full Text PDF

This paper introduces an interferometer for single-shot areal quantitative phase imaging at two wavelengths simultaneously, suitable for use with low coherence sources. It operates in reflection geometry with on-axis illumination, so that it can be conveniently applied to surface texture measurements. The system consists of two identical 4f systems forming the reference and sample arm.

View Article and Find Full Text PDF

Phase-shifting Fringe projection profilometry (FPP) excels in 3D measurements for many macro-scale applications, but as features-of-interest shrink to the microscopic scale, depth-of-field limitations slow measurements and necessitate mechanical adjustments. To address this, we introduce digital holography (DH) for fringe image capture, enabling numerical refocusing of defocused object regions. Our experiments validate this approach and compare depth measurement noise with other DH and FPP methods.

View Article and Find Full Text PDF