We develop a BiBO (BiBO)-based optical parametric amplifier in the spectral region around 2 µm using a Yb:KGW amplifier operating at 100 kHz. The two-stage degenerate optical parametric amplification results in a typical output energy of 30 µJ after compression, spectrum covering 1.7-2.5 µm range, and a pulse duration fully compressible down to 16.4 fs, corresponding to 2.3 cycles. Due to the inline difference frequency generation of the seed pulses, the carrier envelope phase (CEP) is passively stabilized without feedback over 11 hours at the level below 100 mrad including a long-term drift. Short-term statistical analysis in the spectral domain further shows a behavior qualitatively different from that of parametric fluorescence, indicating high degree of suppression of optical parametric fluorescence. The high phase stability together with the few-cycle pulse duration is promising for the investigation of high-field phenomena such as subcycle spectroscopy in solids or high harmonics generation.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.481126DOI Listing

Publication Analysis

Top Keywords

optical parametric
16
parametric amplifier
8
100 khz
8
pulse duration
8
parametric fluorescence
8
parametric
5
highly cep-stable
4
optical
4
cep-stable optical
4
amplifier 2 µm
4

Similar Publications

The integrated frequency comb generator based on Kerr parametric oscillation has led to chip-scale, gigahertz-spaced combs with new applications spanning hyperscale telecommunications, low-noise microwave synthesis, light detection and ranging, and astrophysical spectrometer calibration. Recent progress in lithium niobate (LiNbO) photonic integrated circuits (PICs) has resulted in chip-scale, electro-optic (EO) frequency combs, offering precise comb-line positioning and simple operation without relying on the formation of dissipative Kerr solitons. However, current integrated EO combs face limited spectral coverage due to the large microwave power required to drive the non-resonant capacitive electrodes and the strong intrinsic birefringence of LiNbO.

View Article and Find Full Text PDF

Efficient optical parametric amplification in the thin film lithium niobate waveguides.

Sci Rep

January 2025

Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, South China Normal University, Guangzhou, 510631, People's Republic of China.

Prominent platforms based on thin-film lithium niobate (TFLN) are superior integrated-photonics platforms for efficient optical parametric amplification (OPA), however, previously few studies have been systematically reported the gain-boosting performance of TFLN waveguides compared to bulk LN waveguides. Here, we optimize two TFLN waveguides with dispersion engineering for high-efficiency and ultra-broadband gain of OPA, then report comparative results about the efficient ultra-broadband OPA of TFLN waveguides in the case of low loss, optimized waveguide length and pump power. Note that the efficient ultra-broadband OPA of TFLN waveguides is represented by the peak gain (71.

View Article and Find Full Text PDF

Why do patients with isolated PCL rupture experience no subjective knee joint instability during walking? An biomechanical study.

Front Bioeng Biotechnol

January 2025

Department of Orthopaedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical Universit, Guangzhou, China.

Objective: The aim of this study is to assess the kinematic changes in the knee joint during walking in patients with isolated PCL-deficiency (PCLD) to determine the presence of walking-related joint instability (mechanical instability-abnormal displacement form structural damage). Additionally, the study seeks to provide biomechanical insights into the observed differences between subjective and objective assessments.

Methods: 35 healthy volunteers and 27 patients with isolated PCLD (both involved and uninvolved sides) were included in the study.

View Article and Find Full Text PDF

The Endolift® technique, introduced in 2005, gained popularity among medical and non-medical professionals as a non-surgical approach using subdermal laser devices. However, its widespread adoption lacked a thorough understanding of its physiological interaction, resulting in controversies over its effectiveness and safety. This study aimed to assess the evidence of Endolift® efficacy, parametrization, and safety by analyzing adverse events.

View Article and Find Full Text PDF

Surviving prematurity: retrospective longitudinal study of multisystem consequences in preterm-born individuals from infancy to adolescence.

BMC Pediatr

January 2025

Department of Anatomy, Histology and Anthropology, Institute of Biomedical Sciences, Faculty of Medicine, Vilnius University, Ciurlionio Str. 21, Vilnius, 03101, Lithuania.

Background: Prematurity is linked to diverse and significant health outcomes, but a comprehensive understanding of its long-term multisystem impacts remains limited.

Methods: Retrospective longitudinal cohort study on 417 preterm children born between 2000 and 2015 explores the incidence, dynamics, and interrelationships of health conditions from infancy to adolescence. Data on 1818 diagnoses, categorised by birth weight (BW) and gestational age (GA) and documented according to ICD-10, were analysed using non-parametric tests and negative binomial regression models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!