Introduction: Despite progress in recent years, full antenatal care utilization in India continues to be relatively low and inequitable, particularly between states and districts. In 2015-2016, for example, only 51% of women aged 15-49 in India attended antenatal care at least four times during pregnancy. Using data from the fifth iteration of India's National Family Health Survey, our study aims to explore factors related to the underutilization of antenatal care in India.

Materials And Methods: Data from the most recent live birth in the past five years among women aged 15-49 years were included in our analysis (n = 172,702). Our outcome variable was "adequate antenatal care visits", defined as four or more antenatal visits. Utilizing Andersen's behavioral model, 14 factors were identified as possible explanatory variables. We used univariate and multivariate binary logistic regression models to analyze the association between explanatory variables and adequate visits. Associations were considered statistically significant if p<0.05.

Results: Of the 172,702 women in our sample, 40.75% (95% CI: 40.31-41.18%) had an inadequate number of antenatal care visits. In multivariate analysis, women with less formal education, from poorer households and more rural areas had higher odds of inadequate visits. Regionally, women from Northeastern and Central states had higher odds of inadequate antenatal care utilization compared to those from Southern states. Caste, birth order, and pregnancy intention were also among the variables associated with utilization of antenatal care.

Discussion: Despite improvements in antenatal care utilization, there is cause for concern. Notably, the percentage of Indian women receiving adequate antenatal care visits is still below the global average. Our analysis also reveals a continuity in the groups of women at highest risk for inadequate visits, which may be due to structural drivers of inequality in healthcare access. To improve maternal health and access to antenatal care services, interventions aimed at poverty alleviation, infrastructure development, and education should be pursued.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10166529PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0285454PLOS

Publication Analysis

Top Keywords

antenatal care
20
underutilization antenatal
8
national family
8
family health
8
health survey
8
women aged
8
aged 15-49
8
explanatory variables
8
antenatal
6
care
5

Similar Publications

Objectives: Pregnancies affected by opioid use disorder (OUD) face difficulties with postpartum pain control. This study aims to determine if prenatal anesthesia consultation for patients on medication for opioid use disorder (MOUD) affects maternal postpartum pain control.

Methods: This is a retrospective cohort study of pregnant patients diagnosed on MOUD who received prenatal care and delivered at a single academic institution between January 2017 and July 2023.

View Article and Find Full Text PDF

Dietary Habits of Pregnant Women in Spain: The Role of Nutrition Education in Midwife Consultations.

Nutrients

December 2024

Área de Nutrición y Bromatología, Facultad de Ciencias, Universidad de Burgos, Plaza Misael Bañuelos s/n, 09001 Burgos, Spain.

Correct nutrition during pregnancy is key to guaranteeing success at this stage of a woman's life, and nutritional education is the fundamental tool for achieving this. Studies carried out in different countries indicate that pregnant women do not comply with dietary and nutritional recommendations. Given the lack of evidence available in Spain and the importance of this knowledge to be able to assess the need for nutritional intervention in this group, the aim of this study focused on the current status of the issue in Spain: the quality of the diet of Spanish pregnant women and its conditioning factors.

View Article and Find Full Text PDF

Umbilical Artery Thrombosis Masquerading as Single Umbilical Artery in a Stillbirth.

Diagnostics (Basel)

January 2025

Department of Pathology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.

Umbilical artery thrombosis (UAT) masquerading as a single umbilical artery (SUA) is a rare but critical diagnostic challenge in prenatal care. We described a case of a 22-year-old primigravida with an uneventful obstetric history who presented with reduced fetal movements at 22 weeks of gestation. Ultrasound showed no gross fetal structural anomalies while umbilical artery Doppler flow imaging revealed an isolated SUA.

View Article and Find Full Text PDF

The Emerging Role of Sonoelastography in Pregnancy: Applications in Assessing Maternal and Fetal Health.

Diagnostics (Basel)

December 2024

Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj 16278, Saudi Arabia.

Sonoelastography, a novel ultrasound-based technique, is emerging as a valuable tool in prenatal diagnostics by quantifying tissue elasticity and stiffness in vivo. This narrative review explores the application of sonoelastography in assessing maternal and fetal health, with a focus on cervical, placental, pelvic floor, and fetal tissue evaluations. In the cervix, sonoelastography aids in predicting preterm birth and assessing labor induction success.

View Article and Find Full Text PDF

Effect of abnormal placental cord insertion on hemodynamic change of umbilical cord in a tertiary center: a prospective cohort study.

Postgrad Med J

January 2025

Department of Obstetrics and Gynecology, Chung Shan Hospital, No. 11, Ln. 112, Sec. 4, Ren'ai Rd., Da'an Dist., Taipei City 10689, Taiwan.

Background: Our study aims to evaluate the umbilical vein (UV) hemodynamic change in the prenatal cohort of pregnancies diagnosed with abnormal placental cord insertion (aPCI).

Methods: From January 2022 to December 2022, the fetal umbilical cord insertion site was sonographically examined in singleton fetuses, and umbilical cord blood flow was calculated. The umbilical artery and UV Doppler flow indexes were assessed in cases of normal and abnormal cord insertion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!