A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Mandible Phantom Inclination in the Axial Plane on Image Quality in the Presence of Implant Using Cone-Beam Computer Tomography. | LitMetric

Purpose To assess the effect of 30° phantom inclination on image quality in the presence of an implant using cone-beam computed tomography (CBCT). Materials and methods Three series of eight scans were taken and categorized by a range of 87-90 kVp and 7.1 mA, and 8 mA. For the first CBCT series, the phantom was placed on a flat plane. For the second series, the phantom was inclined at 30° in the axial plane. For the third series, inclined scans were re-oriented and included for statistics. In total, 24 scans were used for statistics. i.e., eight scans at three different planes (flat plane, inclined plane, and re-oriented inclined plane). All the images were analyzed for artifact and contrast-to-noise ratio (CNR) on ImageJ software. Results The inclination of the dry human mandible phantom by 30° reduces the artifact (p <0.05). However, the CNR was not affected by the phantom inclination. Conclusion The appropriate inclination of the head can significantly reduce the metal artifact in the presence of implants and thus improve the CBCT image quality for post-operative follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10122839PMC
http://dx.doi.org/10.7759/cureus.36630DOI Listing

Publication Analysis

Top Keywords

mandible phantom
8
phantom inclination
8
axial plane
8
image quality
8
quality presence
8
presence implant
8
implant cone-beam
8
series phantom
8
flat plane
8
inclined plane
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!