A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MRI safety for leave-on powdered hair thickeners under 1.5-T and 3.0-T MRI: measurement of deflection force, MRI artifact, and evaluation of preexamination screening. | LitMetric

This study aimed to clarify the magnetic resonance imaging (MRI) compatibility of leave-on powdered hair thickeners by evaluating the displacement force and image artifacts of commercially available leave-on powdered hair thickeners on MRI devices and their response to metal and ferromagnetic detectors. Thirteen types of leave-on powdered hair thickeners were studied: nine hair thickener and four foundation types. MRI systems of 1.5 T and 3.0 T were used. Deflection angles and MR image artifacts according to ASTM F2052 and F2119 were evaluated. Handheld metal and ferromagnetic detectors were used to investigate whether hair thickeners could be detected in screening before MRI examinations. The hair thickener type had a deflection angle of 0°, whereas the foundation type had a deflection angle of 90°, indicating a strong physical effect. Significant image artifacts appeared only on the foundation type. The foundation type reacted at distances of less than 10 cm only with a ferromagnetic detector. Foundation-type leave-on powdered hair thickeners containing magnetic substances exhibited strong physical effects and produced significant image artifacts, and those can only be detected by screening with a ferromagnetic detector.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-023-01267-yDOI Listing

Publication Analysis

Top Keywords

hair thickeners
24
leave-on powdered
20
powdered hair
20
image artifacts
16
foundation type
12
hair
8
metal ferromagnetic
8
ferromagnetic detectors
8
hair thickener
8
detected screening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!