Purpose: To compare the effects of three occlusal adjustment methods in different sequences by articulating paper on the delayed occlusal characteristics of single molars.

Methods: Thirty-two implants of first molars were divided into group A(n=12), group B (n=12) and group C (n=12) by sequential adjustment according to random number means, and (100+40), (100+50+30) and (100+40+20) μm sequence occlusal papers were used for occlusal adjustment, respectively. TeeTester was used to measure the delay time and force ratio between prosthesis and adjacent teeth at restoration day, 3 and 6 months after restoration, and to record the number of cases readjusting in each group during follow-up. SPSS 25.0 software package was used for data analysis.

Results: There were significant differences in delay time between groups at restoration day (P<0.05), and 3 and 6 months after restoration, delay time of group C was still smaller than that of group A and B (P<0.05). During follow-up, the time of each group showed a trend of shortening (P<0.05), but there was still delayed occlusion. Compared with group B and C, the force ratio in group A was lower at each time(P<0.05). The ratio of each group showed an increasing trend during follow-up (P<0.05), and group C showed the largest increase (P<0.001). The number of cases readjusting was relatively small in group A, and the most was in group C(P<0.05). There was positive correlation between delay time and force difference of prosthesis and adjacent teeth(P<0.001).

Conclusions: The (100+40) μm sequence group had higher occlusal stability and better clinical applicability. The smaller the occlusal contact space realized by the sequential method, the greater the change might be, which requires close follow-up in clinical practice.

Download full-text PDF

Source

Publication Analysis

Top Keywords

delay time
16
group
14
occlusal adjustment
12
adjustment methods
8
delayed occlusion
8
group n=12
8
μm sequence
8
time force
8
force ratio
8
prosthesis adjacent
8

Similar Publications

An ultrafast algorithm for ultrafast time-resolved coherent Raman spectroscopy.

Commun Chem

January 2025

Energy & Materials Transition, Netherlands Organization for Applied Scientific Research (TNO), Urmonderbaan 22, Geleen, 6167RD, The Netherlands.

Time-resolved coherent Raman spectroscopy (CRS) is a powerful non-linear optical technique for quantitative, in-situ analysis of chemically reacting flows, offering unparalleled accuracy and exceptional spatiotemporal resolution. Its application to large polyatomic molecules, crucial for understanding reaction dynamics, has thus far been limited by the complexity of their rotational-vibrational Raman spectra. Progress in developing comprehensive spectral codes for these molecules, a longstanding goal, has been hindered by prohibitively long computation times required for their spectral synthesis.

View Article and Find Full Text PDF

Introduction: Traumatic injuries are a significant public health concern globally, resulting in substantial mortality, hospitalisation and healthcare burden. Despite the establishment of specialised trauma centres, there remains considerable variability in trauma-care practices and outcomes, particularly in the initial phase of trauma resuscitation in the trauma bay. This stage is prone to preventable errors leading to adverse events (AEs) that can impact patient outcomes.

View Article and Find Full Text PDF

Background: Rapid, accessible, and accurate testing was paramount to an effective US COVID-19 response. Federal partners supported SARS-CoV-2 testing scale-up through an interagency-coordinated approach that focused on expanding supply chains, research and development, validation, and improving patient access. We aimed to provide an overview of the federal efforts to scale up the testing response and study the impact of scale-up.

View Article and Find Full Text PDF

Introduction: Botulinum toxin is an alternative to conventional strabismus surgery for treatment for acute, acquired, comitant esotropia (AACE). Previous studies suggest that the two treatment approaches may be equally effective for 6 months. The purpose of our study was to determine whether botulinum toxin remains as effective as strabismus surgery for 36 months after treatment.

View Article and Find Full Text PDF

Bactericidal activity of gold and silver nanoparticles in solution and supported on polyhihydroxybutyrate nanospheres.

Int J Biol Macromol

January 2025

Centro de Investigaciones en Ciencias Microbiológicas, Instituto de Ciencias, Benemérita Universidad Autónoma de Puebla, Av. San Claudio y Av. 24 Sur, Col. San Manuel Ciudad Universitaria, Puebla C.P. 72570, Mexico. Electronic address:

This work presents the effect of Polyhydroxybutyrate nanospheres (PHB-NSs) on the bacterial activity of plasmonic nanoparticles (NPs). The PHB-NSs were used as a substrate for the metal-NPs. Silver and gold NPs in colloidal solution were synthesized by chemical reduction, while PHB-NSs were synthesized by a physical method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!