Connectivity studies with nuclear medicine systems are scarce in literature. They mainly employ PET imaging and group level analyses due to the low temporal resolution of PET and especially SPECT imaging. Our current study analyses connectivity at an individual level using dynamic SPECT imaging, which has been enabled by the improved temporal resolution performances provided by the 360°CZT cameras. We present the case of an 80-year-old man referred for brain perfusion SPECT imaging for cognitive disorders for whom a dynamic SPECT acquisition was performed utilizing a 360°CZT camera (temporal sampling of 15 frames × 3 s, 10 frames × 15 s, 14 frames × 30 s), followed by a conventional static acquisition of 15 m. Functional SPECT connectivity (fSPECT) was assessed through a seed correlation analysis and 5 well-known resting-state networks were identified: the executive, the default mode, the sensory motor, the salience, and the visual networks. This case report supports the feasibility of fSPECT imaging to identify well known resting-state networks, thanks to the novel properties of a 360°CZT camera, and opens the way to the development of more dedicated functional connectivity studies using brain perfusion SPECT imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10157397PMC
http://dx.doi.org/10.3389/fnhum.2023.1125765DOI Listing

Publication Analysis

Top Keywords

spect imaging
20
resting-state networks
12
brain perfusion
12
perfusion spect
12
case report
8
connectivity studies
8
temporal resolution
8
dynamic spect
8
360°czt camera
8
frames frames
8

Similar Publications

Fabrication of 3D printed hollow spheres for quality control and feasibility for use with xSPECT bone.

Phys Eng Sci Med

December 2024

Department of Medical Imaging and Nuclear Medicine, Gosford Hospital, Building K3, Gosford, NSW, Australia.

Quantitative accuracy and constancy of Siemens xSPECT Bone quantitative reconstruction algorithm (xBone) can be monitored using activity-filled hollow spheres, which could be 3D printed (3DP) to increase accessibility to phantoms. One concern is that 3D prints can have air gaps in the walls which may pose issues for attenuation correction and xBone tissue zone mapping. This study assessed the feasibility of using 3DP spheres (3DP-S) with materials PLA, PETG and Resin as substitutes for commercial hollow spheres (C-S).

View Article and Find Full Text PDF

Purpose: [Tc]Tc-HYNIC-iPSMA is a novel technetium-99m-labelled small molecule inhibitor of the prostate-specific membrane antigen (PSMA) for detecting prostate cancer (PC). The objective of this registry was to collect and evaluate [Tc]Tc-HYNIC-iPSMA patient data and images to establish the safety and tolerability, and clinical utility of this agent in imaging at different stages of PC.

Methods: Patients 18 to 80 years old with primary staging and metastatic PC were eligible.

View Article and Find Full Text PDF

Diagnostic criteria for temporomandibular joint osteoarthritis using standardized uptake value in single-photon emission computed tomography-computed tomography.

Sci Rep

December 2024

Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Gangnam Severance Hospital, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea.

This study aimed to investigate the cutoff values of standardized uptake values (SUVs) and their accuracy using single-photon emission computed tomography-computed tomography (SPECT-CT) for temporomandibular joint (TMJ) osteoarthritis (OA) based on magnetic resonance imaging (MRI) and clinical examination. We included 106 joints of 53 patients with TMJ OA. SUVmax and SUVpeak of each TMJ was measured.

View Article and Find Full Text PDF

Aim: Coronary artery disease (CAD) is a primary cause of mortality, prompting ongoing research into noninvasive diagnostic modalities. This study aimed to evaluate the diagnostic efficacy of exercise electrocardiography testing (EET) combined with cadmium zinc tellurium cardiac-dedicated single photon emission computed tomography (CZT-SPECT) imaging for CAD.

Materials And Methods: CZT-SPECT and EET were examined in 124 patients aged 20-85 years, followed by coronary angiography to evaluate the sensitivity, specificity, positive predictive value, and negative predictive value of EET/CZT-SPECT alone and in combination.

View Article and Find Full Text PDF

Purpose: This study aimed to elucidate the distribution of intracranial gamma-aminobutyric acid (GABA) receptors in patients with infantile epileptic spasms syndrome (IESS) of normal brain MRI findings using I-iomazenil single-photon emission computed tomography (IMZ-SPECT).

Methods: This retrospective study compared IMZ-SPECT images from 20 patients with IESS of unknown etiology with normal brain MRI (unknown IESS group) and 23 patients with developmentally normal epilepsy of the same age (developmentally normal group). A three-dimensional stereotactic region of interest (ROI) template was used to divide the brain into 24 segments (left and right callosomarginal, precentral, central, parietal, angular, temporal, posterior cerebral, pericallosal, lenticular nucleus, thalamus, hippocampus, and cerebellum), and the mean accumulation of I-iomazenil in each ROI was calculated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!