Objective: To determine, by biomechanical analysis, safe patellar cut limits in anterior cruciate ligament (ACL) reconstruction that minimize fracture risks.
Methods: From three-dimensional reconstruction, triangular cuts were made in the patella, with a depth of 6.5 mm and variable width and length (10 to 20 mm and 8 to 12 mm, respectively, both with an interval of 1 mm). The combinations of cuts constituted 55 models for tests, with five variations in width and 11 variations in length, tested with the finite element method (FEM).
Results: The mean of the localized principal maximum (traction force) values was 4.36 Pa (SD 0.87 ± 0.76) and the localized principal minimum (compression force) was -4.33 Pa (SD 1.05 ± 1.11). Comparing width and length to the tension force of the values of the main maximum, we found statistical significance from 11 mm for width and 13 mm for length.
Conclusion: In ACL reconstruction, the removal of the patellar bone fragment is safe for fragments smaller than 11 mm in width and 13 mm in length, which corresponds to 24% of the width and 28% of the length of the patella used.