AI Article Synopsis

  • The study focuses on improving a method for accurately measuring total iron in Iron Carbohydrate Colloid Drug Products, which are important for intravenous formulations.
  • It utilizes a potentiometric redox iodometry technique that provides higher accuracy and sensitivity compared to traditional methods, ensuring reliable endpoint determination during the measurement.
  • The validated method demonstrated high precision, linearity, and robustness, making it suitable for widespread application in quality control of intravenous iron formulations.

Article Abstract

Background: Iron carbohydrate complexes are colloidal dispersions made up of polynuclear Fe(III)-oxyhydroxide cores surrounded by a carbohydrate shell that stabilizes the complex in iron colloidal formulations. The current study provides an improved method that is precise, accurate, and linear for quantifying total iron in most Iron Carbohydrate Colloid Drug Products.

Methods: Redox iodometry with a potentiometric determination is used to evaluate total iron in intravenous formulations. The visual indicator approach is more prone to fluctuations at endpoint calculations. Hence, the voltage potential approach is widely accepted as it is more accurate and sensitive. It tracks the actual change in activity that coincides with the equivalence point that is finally considered an endpoint. The principle is based on the idea that ferric iron in formulation reduces to ferrous iron in the presence of the iodide, which oxidizes to iodine. The released iodine is titrated using sodium thiosulfate.

Results: The proposed method was precise, with %RSD (relative standard deviation) not more than 1. The method was linear between 80% and 120%, with a linear regression of 0.999. The percent recovery ranged from 98.20 to 99.98 for the concentration ranges of 80-120. The method's robustness was checked by various analysts using different reagent grades.

Conclusion: The proposed potentiometric determination method was precise, accurate, linear, and sensitive. The method was successfully validated, and the total iron content determined for commercial batches agrees with the iron claim on the label. Therefore, this method can be adapted widely for total iron content determination in any Intravenous formulation currently available on the market. The proposed method is more accessible at the Quality Control facilities on an industrial scale.

Download full-text PDF

Source
http://dx.doi.org/10.2174/2211738511666230507190224DOI Listing

Publication Analysis

Top Keywords

total iron
20
iron
12
method precise
12
iron colloidal
8
iron carbohydrate
8
precise accurate
8
accurate linear
8
potentiometric determination
8
proposed method
8
iron content
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!