Chest-to-arm tunneling technique for central venous access devices in neonates.

J Vasc Access

Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili, Brescia, Italy.

Published: May 2024

Background: Chest-to-arm (CTA) tunneling technique has been described recently as an alternative option to exit site of the catheter in the infraclavicular area.

Method: We report our experience with ultrasound-guided centrally inserted central catheters (CICCs) placed using CTA tunneling in six neonates. All central venous catheters were positioned with ultrasound guidance and real-time tip location.

Results: There were no insertion-related complications; all devices were correctly positioned at the first attempt. During the follow-up, we found no catheter-related thrombosis, infections, or catheter malfunction. No tip position-related complications. Only one case of secondary malposition was reported.

Conclusion: In our experience, the CTA tunneling technique is reliable, safe, and feasible in the neonate even from the first hours of life, as well as for preterm newborns; it could be a valid alternative to the usual exit site.