Von Willebrand disease (VWD) is a common bleeding disorder of platelet adhesion with six currently recognized subtypes. Laboratory diagnosis consists of an initial test panel including antigen, activity and factor VIII measurements, sometimes followed by further specialized testing. VWF activity/antigen testing ratios help to differentiate type 1 and type 2 disease, which is important for selection of proper therapy. Recommended ratio cutoffs differ by guideline, ranging from 0.5 to 0.7, with 0.7 commonly recommended. The ratio cutoff used affects the sensitivity and specificity for type 2 diagnosis. Variability in VWD due to underlying mutations and patient factors, as well as variability in VWF tests, impact the accuracy of ratios for VWD subtyping. This review discusses the use of activity/antigen ratios in the diagnosis and subtyping of VWD with a focus on technical aspects of the tests.