Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This work presents a methodology for polycyclic aromatic hydrocarbons (PAHs) trapping from vehicular emissions using an in-tube extraction device (IT-FEx). Trapping selectivity studies were conducted, evaluating the interaction profile between the aromatic compounds and the polymeric phase (composed of polydimethylsiloxane and internal to the IT-FEx devices), as in an aqueous equilibrium system (25 min of sampling), and as in gaseous dynamic phase (30 s of sampling), regarding a qualitative evaluation. The adsorption profiles were similar, with greater affinity for medium-sized PAHs (four aromatic rings) than for the smaller (one to three rings) and larger (five to six rings). The device was attached to a vehicle emission sampler to evaluate the qualitative emission of diesel-powered vehicles. Certain PAHs, such as phenanthrene, fluoranthene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[k]fluoranthene, were effectively trapped by the IT-FEx device and detected by the GC-BID analysis. Finally, it was possible to develop a process that combined the steps of sample preparation and instrumental analysis, using the IT-FEx device and applying it to the gaseous matrix in the dynamic phase; until then, little was elucidated regarding the use of this apparatus. This sampling device, combined with analysis by gas chromatography with a barrier ionization discharge detector (GC-BID), is a powerful tool for identifying many compounds from vehicular emissions and does not require solvents in sample preparation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2023.463995 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!