Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10162678PMC
http://dx.doi.org/10.1093/bjsopen/zrad036DOI Listing

Publication Analysis

Top Keywords

non-invasive thoracoabdominal
4
thoracoabdominal mapping
4
mapping postoesophagectomy
4
postoesophagectomy conduit
4
conduit function
4
non-invasive
1
mapping
1
postoesophagectomy
1
conduit
1
function
1

Similar Publications

Structured Light Plethysmography for Non-Invasive Assessment of Respiratory Pattern in Spinal Muscular Atrophy Type 1.

J Clin Med

December 2023

Paediatric Neurology and Muscle Disease Unit, IRCCS Istituto Giannina Gaslini, 16147 Genova, Italy.

Background: Spinal muscular atrophy (SMA) type 1 is a severe condition leading to early respiratory failure. Treatment options have become available, yet respiratory outcome measures in SMA type 1 are limited. The aim of this study was to assess the respiratory pattern in SMA type 1 patients via structured light plethysmography (SLP).

View Article and Find Full Text PDF

Neural signals-based respiratory motion tracking: a proof-of-concept study.

Phys Med Biol

September 2023

Radiotherapy Physics and Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, People's Republic of China.

Respiratory motion tracking techniques can provide optimal treatment accuracy for thoracoabdominal radiotherapy and robotic surgery. However, conventional imaging-based respiratory motion tracking techniques are time-lagged owing to the system latency of medical linear accelerators and surgical robots. This study aims to investigate the precursor time of respiratory-related neural signals and analyze the potential of neural signals-based respiratory motion tracking.

View Article and Find Full Text PDF

The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual's health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements.

View Article and Find Full Text PDF

Lung and chest wall volume during vital capacity manoeuvre in Osteogenesis Imperfecta.

Orphanet J Rare Dis

October 2022

Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, piazza Leonardo Da Vinci, 20133, Milan, Italy.

Background: Although Osteogenesis Imperfecta (OI) affects the connective tissue, pulmonary function might be compromised because of thoracic deformities. OI is known to be a restrictive lung disease, but spirometry provides global measurement without localizing the site of the restriction. Opto-electronic plethysmography (OEP), is a non-invasive method able to underline altered respiratory function as well as ventilatory thoraco-abdominal paradoxes during spontaneous breathing.

View Article and Find Full Text PDF