Purpose: To systematically assess test performance of patient-adapted D-dimer cut-offs for the diagnosis of venous thromboembolism (VTE).

Methods: Systematic review and analysis of articles published in PubMed, Embase, ClinicalTrials.gov, and Cochrane Library databases. Investigations assessing patient-adjusted D-dimer thresholds for the exclusion of VTE were included. A hierarchical summary receiver operating characteristic model was used to assess diagnostic accuracy. Risk of bias was assessed by Quality Assessment of Diagnostic Accuracy Studies 2 score.

Results: A total of 68 studies involving 141,880 patients met the inclusion criteria. The standard cut-off revealed a sensitivity of 0.99 (95% confidence interval [CI] 0.98-0.99) and specificity of 0.23 (95% CI 0.16-0.31). Sensitivity was comparable to the standard cut-off for age-adjustment (0.97 [95% CI 0.96-0.98]) and YEARS algorithm (0.98 [95% CI 0.91-1.00]) but lower for pretest probability (PTP)-adjusted (0.95 [95% CI 0.89-0.98) and COVID-19-adapted thresholds (0.93 [95% CI 0.82-0.98]). Specificity was significantly higher across all adjustment strategies (age: 0.43 [95% CI 0.36-0.50]; PTP: 0.63 [95% CI 0.51-0.73]; YEARS algorithm: 0.65 [95% CI 0.39-0.84]; and COVID-19: 0.51 [95% CI 0.40-0.63]). The YEARS algorithm provided the best negative likelihood ratio (0.03 [95% CI 0.01-0.15]), followed by age-adjusted (both 0.07 [95% CI 0.05-0.09]), PTP (0.08 [95% CI 0.04-0.17), and COVID-19-adjusted thresholds (0.13 [95% CI 0.05-0.32]).

Conclusions: This study indicates that adjustment of D-dimer thresholds to patient-specific factors is safe and embodies considerable potential for reduction of imaging. However, robustness, safety, and efficiency vary considerably among different adjustment strategies with a high degree of heterogeneity.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joim.13650DOI Listing

Publication Analysis

Top Keywords

[95%
12
years algorithm
12
patient-adjusted d-dimer
8
diagnosis venous
8
systematic review
8
d-dimer thresholds
8
diagnostic accuracy
8
standard cut-off
8
adjustment strategies
8
utility limitations
4

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!