A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precise measurement for line structure light vision sensor with large range. | LitMetric

High precision and large measurement range are the target of any one three-dimensional scanner. For a line structure light vision sensor, measurement precision depends on its calibration results, i.e., determining mathematical expression of the light plane in camera coordinate system. However, as calibration results are locally optimal solutions, high precise measurement in a large range is difficult. In this paper, we give a precise measurement method and the corresponding calibration procedure for a line structure light vision sensor with a large measurement range. A motorized linear translation stages with a travel range of 150 mm and a planar target which is a surface plate with a machining precision of 0.05 mm are utilized. With the help of the linear translation stage and the planar target, functions which gives the relationship between center point of the laser stripe and the perpendicular/ horizontal distance are obtained. Once image of light stripe is captured, we can get a precise measurement result from the normalized feature points. Compared with a traditional measurement method, distortion compensation is not necessary and precision of measurement is improved significantly. Experiments show that root mean square error of measurement results according to our proposed method is reduced by 64.67% related to the traditional method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160092PMC
http://dx.doi.org/10.1038/s41598-023-34428-wDOI Listing

Publication Analysis

Top Keywords

precise measurement
16
structure light
12
light vision
12
vision sensor
12
measurement
9
sensor large
8
large range
8
large measurement
8
measurement range
8
measurement method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!